EMG patterns during assisted walking in the exoskeleton

نویسندگان

  • Francesca Sylos-Labini
  • Valentina La Scaleia
  • Andrea d'Avella
  • Iolanda Pisotta
  • Federica Tamburella
  • Giorgio Scivoletto
  • Marco Molinari
  • Shiqian Wang
  • Letian Wang
  • Edwin van Asseldonk
  • Herman van der Kooij
  • Thomas Hoellinger
  • Guy Cheron
  • Freygardur Thorsteinsson
  • Michel Ilzkovitz
  • Jeremi Gancet
  • Ralf Hauffe
  • Frank Zanov
  • Francesco Lacquaniti
  • Yuri P. Ivanenko
چکیده

Neuroprosthetic technology and robotic exoskeletons are being developed to facilitate stepping, reduce muscle efforts, and promote motor recovery. Nevertheless, the guidance forces of an exoskeleton may influence the sensory inputs, sensorimotor interactions and resulting muscle activity patterns during stepping. The aim of this study was to report the muscle activation patterns in a sample of intact and injured subjects while walking with a robotic exoskeleton and, in particular, to quantify the level of muscle activity during assisted gait. We recorded electromyographic (EMG) activity of different leg and arm muscles during overground walking in an exoskeleton in six healthy individuals and four spinal cord injury (SCI) participants. In SCI patients, EMG activity of the upper limb muscles was augmented while activation of leg muscles was typically small. Contrary to our expectations, however, in neurologically intact subjects, EMG activity of leg muscles was similar or even larger during exoskeleton-assisted walking compared to normal overground walking. In addition, significant variations in the EMG waveforms were found across different walking conditions. The most variable pattern was observed in the hamstring muscles. Overall, the results are consistent with a non-linear reorganization of the locomotor output when using the robotic stepping devices. The findings may contribute to our understanding of human-machine interactions and adaptation of locomotor activity patterns.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gastrocnemius Myoelectric Control of a Robotic Hip Exoskeleton Can Reduce the User's Lower-Limb Muscle Activities at Push Off

We present a novel assistive control strategy for a robotic hip exoskeleton for assisting hip flexion/extension, based on a proportional Electromyography (EMG) strategy. The novelty of the proposed controller relies on the use of the Gastrocnemius Medialis (GM) EMG signal instead of a hip flexor muscle, to control the hip flexion torque. This strategy has two main advantages: first, avoiding th...

متن کامل

Locomotor adaptation to a soleus EMG-controlled antagonistic exoskeleton.

Locomotor adaptation in humans is not well understood. To provide insight into the neural reorganization that occurs following a significant disruption to one's learned neuromuscular map relating a given motor command to its resulting muscular action, we tied the mechanical action of a robotic exoskeleton to the electromyography (EMG) profile of the soleus muscle during walking. The powered exo...

متن کامل

An Electromyography analysis of lower limb muscles for different locomotion activities

In this study, surface electromyography (EMG) signals of the Gastrocnemius, Tibialis anterior and Soleus muscles were recorded on various subject during their daily life activities such as walking and stair ascent and decent. The lowerlimb muscle activities have been studied to enable power-assist robotic systems to estimate human lower-limb muscle activities based on muscle electromyographic (...

متن کامل

Metabolic costs and muscle activity patterns during robotic- and therapist-assisted treadmill walking in individuals with incomplete spinal cord injury.

BACKGROUND AND PURPOSE Robotic devices that provide passive guidance and stabilization of the legs and trunk during treadmill stepping may increase the delivery of locomotor training to subjects with neurological injury. Lower-extremity guidance also may reduce voluntary muscle activity as compared with compliant assistance provided by therapists. The purpose of this study was to investigate di...

متن کامل

Automatic Setting Procedure for Exoskeleton-Assisted Overground Gait: Proof of Concept on Stroke Population

Stroke-related locomotor impairments are often associated with abnormal timing and intensity of recruitment of the affected and non-affected lower limb muscles. Restoring the proper lower limbs muscles activation is a key factor to facilitate recovery of gait capacity and performance, and to reduce maladaptive plasticity. Ekso is a wearable powered exoskeleton robot able to support over-ground ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014