Ozone Monitoring Instrument (OMI), launched in July 2004, is dedicated to the monitoring of the Earth’s ozone, air quality and climate. OMI is the successor of the Total Ozone Mapping Spectrometer (TOMS) instruments and provides among other atmospheric and radiometric quantities the total column of ozone (TOC), the surface ultraviolet (UV) irradiance at several wavelengths, the erythemal dose rates and the erythemal daily doses. The main objective of this work is to compare OMI data with data from ground-based instruments in order to use OMI products (collection 2) for scientific studies. The Laboratoire d’Optique Atmosphérique (LOA) located in Villeneuve d’Ascq (VdA) in the north of France performs solar UV measurements using a spectroradiometer. The site of Briançon in the French Southern Alps is also equipped with a spectroradiometer operated by Interaction Rayonnement Solaire Atmosphère (IRSA). The OMI total ozone column data is obtained from the OMI-TOMS and OMI-DOAS algorithms. The comparison between the TOC retrieved with ground-based measurements and OMI-TOMS data shows good agreement at both sites for all sky conditions with a relative difference for most of points better than 5%. For OMI-DOAS data, the agreement is generally better than 7% and these data show a significant dependence on solar zenith angle. Comparisons of spectral UV on clear sky conditions are also satisfying with relative differences smaller than 10% except at solar zenith angles larger than 65. On the contrary, results of comparCorrespondence to: V. Buchard ([email protected]) isons of the erythemal dose rates and erythemal daily doses for clear sky show that OMI overestimates surface UV doses at VdA by about 15% and that on cloudy skies, the bias increases. At Briançon, such a bias is observed if data corresponding to snow-covered surface are excluded.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interactive comment on “Comparison of OMI ozone and UV irradiance data with ground-based measurements at two French sites” by V. Buchard

Answers to referee #2 comments received and published on 10 April 2008, on the manuscript: "Comparison of OMI ozone and UV irradiance data with ground-based measurements at two French sites." General comments : This well-written paper presents a comparison between OMI (TOMS-like and DOASlike) estimated total ozone content (TOC) and the value retrieved from two Jobin Yvon spectroradiometers at t...

متن کامل

Measurements of UV irradiance within the area of one satellite pixel

A measurement campaign was performed in the region of Vienna and its surroundings from May to July 2007. Within the scope of this campaign erythemal UV was measured at six ground stations within a radius of 30 km. First, the homogeneity of the UV levels within the area of one satellite pixel was studied. Second, the ground UV was compared to ground UV retrieved by the ozone monitoring instrumen...

متن کامل

Comparison of UV irradiances from Aura/Ozone Monitoring Instrument (OMI) with Brewer measurements at El Arenosillo (Spain) – Part 1: Analysis of parameter influence

The main objective of this study is to compare the erythemal UV irradiance (UVER) and spectral UV irradiances (at 305, 310 and 324 nm) from the Ozone Monitoring Instrument (OMI) onboard NASA EOS/Aura polar sun-synchronous satellite (launched in July 2004, local equator crossing time 01:45 p.m.) with ground-based measurements from the Brewer spectrophotometer #150 located at El Arenosillo (South...

متن کامل

Comparison of UV irradiances from Aura/Ozone Monitoring Instrument (OMI) with Brewer measurements at El Arenosillo (Spain) – Part 2: Analysis of site aerosol influence

Several validation studies have shown a notable overestimation of the clear sky ultraviolet (UV) irradiance at the Earth’s surface derived from satellite sensors such as the Total Ozone Mapping Spectrometer (TOMS) and the Ozone Monitoring Instrument (OMI) with respect to groundbased UV data at many locations. Most of this positive bias is attributed to boundary layer aerosol absorption that is ...

متن کامل

Mesoscale distributions of UV spectral irradiance obtained by merging satellite remote sensing and ground-based measurements

Global atmospheric trends in ozone column amount has focused attention on the environmental risk of exposure to ultraviolet (UV) radiation. Monitoring UV irradiance in diverse and remote locations is necessary to understand the variability of exposure, dose rates and resultant vulnerability of ecological systems. The USDA UV-B Monitoring Program maintains a wide network for ground-based continu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008