Immune response to polyglycolic acid implants.
نویسندگان
چکیده
Cytological analysis of material aspirated from the effusion which occasionally develops around a polyglycolic acid (PGA) osteosynthesis implant showed a predominance of inflammatory monocytes and in particular lymphocytes. In order to discover whether PGA implants are immunologically inert, density gradient-isolated peripheral blood mononuclear cells were cultured in 0.2 ml of 10% delta FCS-RPMI 1640 culture medium supplemented with 10 mg PGA. Phytohaemagglutinin (PHA) lectin, a purified protein derivate of tuberculin (PPD) antigen and culture medium alone were used as positive and negative controls. We studied lymphocyte activation kinetics on days 0, 1, 3 and 5. Major histocompatibility complex locus II antigen (MHC locus II antigen) and interleukin-2 receptor (IL-2R) expression were analysed using the avidin-biotin-peroxidase complex (ABC) method and lymphocyte DNA synthesis by using 3H-thymidine incorporation and beta-scintillation counting. Especially on culture days 0 and 1, lymphocytes and monocytes were seen by light microscopy to be attached to PGA particles. However, our results show no PGA-induced lymphocyte DNA synthesis, but PGA-induced MHC locus II antigen and IL-2R activation marker expression was seen, greater than in negative controls, but less than that seen in PPD antigen driven lymphocyte response. This suggests that PGA is an immunologically inert implant material, but it does seem to induce inflammatory mononuclear cell migration and adhesion, leading to a slight non-specific lymphocyte activation. This activation is lower than that seen in mitogen and antigen-driven lymphocyte responses.
منابع مشابه
Implantable Medical Devices
Abbreviations MEMS Microelectromechanical systems NEMS Nano-electromechanical systems PCL Polycaprolactone PET Polyethylene terephthalate PGA Polyglycolic acid PLA Polylactic acid PU Polyurethane PTFE Poly(tetrafl uoroethylene) PMMA Polymethylmethacrylate UHMWPE Ultrahigh molecular weight polyethylene
متن کاملAdverse tissue reactions to bioabsorbable fixation devices.
Among 2528 patients operated on using pins, rods, bolts, and screws made of polyglycolic acid or polylactic acid, 108 (4.3%) were affected by a clinically significant local inflammatory, sterile tissue reaction. The three most common indications for the use of these fixation devices were a displaced malleolar fracture, a chevron osteotomy for hallux valgus, and a displaced fracture of the radia...
متن کاملTissue restoration after resorption of polyglycolide and poly-laevo-lactic acid screws.
Despite worldwide clinical use of bio-absorbable devices for internal fixation in orthopaedic surgery, the degradation behaviour and tissue replacement of these implants are not fully understood. In a long-term experimental study, we have determined the patterns of tissue restoration 36 and 54 months after implantation of polyglycolic acid and poly-laevo-lactic acid screws in the distal femur o...
متن کاملThe effects of dynamic compressive loading on biodegradable implants of 50-50% polylactic Acid-polyglycolic Acid.
Biodegradable implants that release growth factors or other bioactive agents in a controlled manner are investigated to enhance the repair of musculoskeletal tissues. In this study, the in vitro release characteristics and mechanical properties of a 50:50 polylactic acid/polyglycolic acid two phase implant were examined over a 6-week period under no-load conditions or under a cyclic compressive...
متن کاملChitosan implants in the rat spinal cord: biocompatibility and biodegradation.
Biomaterials are becoming increasingly popular for use in spinal cord repair, but few studies have investigated their long-term biocompatibility in central nervous system tissue. In this study, chitosan was compared with two commercial materials, degradable polyglycolide (vicryl and polyglactin 910) and nondegradable expanded poly(tetrafluoroethylene) (Gore-Tex and ePTFE), in terms of host tiss...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 72 4 شماره
صفحات -
تاریخ انتشار 1990