The use of isothermal heat conduction microcalorimetry to evaluate drug stability in tablets.

نویسندگان

  • T Selzer
  • M Radau
  • J Kreuter
چکیده

Isothermal heat conduction microcalorimetry was used to evaluate chemical stability of a solid drug in tablets. A variety of mixtures were compressed to flat faced tablets of 300 mg weight and 10 mm diameter. The content of drug amounted to 10%. Besides drug containing tablets, also placebo tablets as well as the non compressed mixtures were examined by microcalorimetry at 80 degrees C. The excipient Emcompress exhibited a substantially high exothermic heat flow that was due to a change in crystallinity. For Emcompress containing tablets this interfering signal resulted in such a way that the calorimetric data did not reflect the drug decomposition with sufficient accuracy. In the case of the other preparations the heat flow of the excipients were low, and the calorimetric data did reflect the drug decomposition. The stability increased with increasing content of CaHPO4, respectively, with decreasing content of water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of heat-conduction microcalorimetry in pharmaceutical stability studies. I. Precision and accuracy for static experiments in glass vials.

inTroDuCTion In the preformulation stage of pharmaceuticals, accelerated stability studies using data from DSC/DTA studies, combined with analytical techniques such as spectroscopy and HPLC are the normal methods used to collect data. The possibility to use isothermal heat conduction microcalorimetry to obtain rate constants at close to, or at room temperatures could therefore be of interest fo...

متن کامل

Use of isothermal heat-conduction microcalorimetry (IHCMC) for the evaluation of synthetic biomaterials.

Isothermal heat-conduction microcalorimetry (IHCMC) allows measurement of extremely small rates of heat flow-on the order of 0.1 microwatt. This provides, for example, the ability to directly observe-and quantitate in a few days-rates of degradation as low as 1% per year at body temperature, in solid material samples of a few grams. Also, one method of IHCMC data analysis allows direct determin...

متن کامل

Biomedical Use of Isothermal Microcalorimeters

Isothermal microcalorimetry is becoming widely used for monitoring biological activities in vitro. Microcalorimeters are now able to measure heat production rates of less than a microwatt. As a result, metabolism and growth of relatively small numbers of cultured bacteria, protozoans, human cells and even small animals can be monitored continuously and extremely accurately at any chosen tempera...

متن کامل

Isothermal Microcalorimetry, a New Tool to Monitor Drug Action against Trypanosoma brucei and Plasmodium falciparum

Isothermal microcalorimetry is an established tool to measure heat flow of physical, chemical or biological processes. The metabolism of viable cells produces heat, and if sufficient cells are present, their heat production can be assessed by this method. In this study, we investigated the heat flow of two medically important protozoans, Trypanosoma brucei rhodesiense and Plasmodium falciparum....

متن کامل

Microcalorimetry: a response to challenges in modern biotechnology

Almost any process in life is accompanied by heat changes which can be monitored by isothermal titration calorimetry (ITC) and differential scanning calorimetry (DSC). Both techniques are now established tools in fundamental research but over the last decade a clear tendency towards more problem-driven applications is noted. This review aims at summarizing these problem-oriented applications of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of pharmaceutics

دوره 184 2  شماره 

صفحات  -

تاریخ انتشار 1999