Strain and Damage in Silicon Due to a Deep Oxygen Implantation

نویسنده

  • THAD VREELAND
چکیده

Silicon wafers, implanted with oxygen at 550°C to form a buried oxide layer have been examined with TEM and x-ray diffraction. Implantation damage increased with depth up to 1500 ~ where some amorphous regions were seen. The amorphous region extended for -4500 A to a damaged crystalline region 1000 ~ thick. Double crystal x-ray rocking curves of the as-implanted and of annealed crystals were obtained and analyzed. The strain normal to the (100) surface in the as-implanted crystalline Si did not exceed +0.05%. After an argon anneal, the strain disappeared, leaving a crystal with a lower density of extended defects and no measureable misorientation of surface or deep layers. In marked contrast, an anneal in a hydrogen atmosphere exhibited no normal strain but contained regions above the oxide layer which differed in orientation from the substrate. The misorientation ranged up to -0.1 degree.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

VERY DEEP TRENCHES IN SILICON WAFER USING DRIE METHOD WITH ALUMINUM MASK

Abstract: In this paper, a DRIE process for fabricating MEMS silicon trenches with a depth of more than 250 m is described. The DRIE was produced in oxygen-added sulfur hexafluoride (SF6) plasma, with sample cooling to cryogenic temperature using a Plasmalab System 100 ICP 180 at different RF powers. A series of experiments were performed to determine the etch rate and selectivity of the some m...

متن کامل

Electrically active defects due to end-of-ion-range damage in silicon irradiated with MeV Ar+ ions

Damage induced by MeV Ar+ ion implantation and end of range defects in Si have been studied by capacitance-voltage, thermally stimulated capacitance, deep level transient spectroscopy (DLTS) and time analyzed transient spectroscopy (TATS). Unlike earlier studies, which focus on defects induced during post-implantation annealing steps, we study asimplanted p-type silicon samples. We report the o...

متن کامل

Role of Oxygen on the Implantation Related Residual Defects in Silicon

The role of oxygen concentration on the formatiordevolution of residual defects in implanted and rapid thermal annealed silicon was studied in samples with various oxygen concentrations. Photoluminescence (PL) study showed a strong correlation between the D-line intensity and the oxygen concentration. Transmission electron microscopy (TEM) measurements also suggested the extended defects were m...

متن کامل

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

Generation and recovery of strain in 28Si-implanted pseudomorphic GeSi films on Si(100)

Effects of ion implantation of 320 keV “Si at room temperature in pseudomorphic metastable Ge$i,-, (x-0.04, 0.09, 0.13) layers 170 nm thick grown on Si( 100) wafers were characterized by x-ray double-crystal diffractometry and MeV 4He channeling spectrometry. The damage induced by implantation produces additional compressive strain in the Ge$i, _ x layers, superimposed on the intrinsic compress...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014