Author Response: Dimensional and Flow Properties of the EX-PRESS Glaucoma Drainage Device.
نویسندگان
چکیده
We read with interest the article by Sheybani et al. demonstrating the assessment of fluid dynamics and flow control between the XEN 45 microfistula implant (AqueSys, Aliso Viejo, CA, USA), EX-PRESS implant (Alcon Laboratories, Inc., Fort Worth, TX, USA), and silicone tubing from a Baerveldt implant (Abbott Medical Optics, Abbott Park, IL, USA). The authors demonstrated that the Hagen-Poiseuille equation can be used to calculate the required dimensions of a tube that would prevent hypotony at average aqueous humour production and that the EX-PRESS device, when placed without a sclera flap, results in hypotony. The article describes the EX-PRESS device to have an opening of 200 lm in inner diameter that tapers to a 50-lm inner lumen. Our group has previously reported our evaluation of the EX-PRESS device. Two device models are available, the P50 and P200, with advertised 50and 200-lm luminal internal diameters (ID), respectively. Esterman et al. previously reported that the resistance to the flow with the EX-PRESS device would decrease by 256 times if the luminal diameter were increased by 4 times, as expected from the HagenPoiseuille equation. However, they only observed a resistance value obtained with the P200 device in the order of 6 to 7 times lower than the P50 device, a finding we previously corroborated in our own study. The reduction in resistance with increased lumen ID cannot be explained with the Hagen-Poiseuille equation on the basis of the lumen ID criteria alone. On scanning electron microscopy, we observed that the internal diameters of the lumen of the P50 and P200 were in the region of 200 lm at the subconjunctival space and anterior chamber end. We confirmed with Alcon, Inc. that the P50 differs from the P200 only in having a 150-lm diameter bar lying across its lumen in the middle of the device. The P50 and P200 devices also have a side orifice at the anterior chamber end of their bodies, which means they do not have a constant circular cross section. This, together with the presence of the bar lying across the lumen of the P50 device, means that Poiseuille’s Law is not applicable. Sheybani et al. also state that the EX-PRESS does not provide significant outflow resistance. We too observed that there were minimal differences in pressures between the EXPRESS device and a typical trabeculectomy. However, we observed that device implantation resulted in less variability in pressure readings. This may be due to more consistent lumen sizes with small tolerances, compared to making a sclerostomy with a punching device or knife. We also observed that more manipulation was required subjectively with a smaller 27-gauge (G) versus 25-G needle stab on device insertion. This may result in a poorer fit around the body of the device, resulting in leakage. We agree with Sheybani et al. that use of the EX-PRESS device without a scleral flap carries significant risk of hypotony and has similar equilibrium pressures as the trabeculectomy procedure. We would highlight that the effective luminal diameter of the P50 is much larger than 50 lm and that intraoperative surgical technique may reduce tissue manipulation and, therefore, reduce postoperative pressure fluctuations.
منابع مشابه
MRI of the Ex-PRESS stainless steel glaucoma drainage device.
AIM To evaluate the magnetic properties of the Ex-PRESS stainless steel glaucoma drainage device during MRI. DESIGN Experimental study. METHODS The Ex-PRESS glaucoma drainage device (316L stainless steel) was examined for magnetic field interactions under standard 1.5, 3.0, and 4.7 T MRI scanning protocols. Testing included measurements of translational and rotational motion of the device i...
متن کاملThe Surgical Treatment of Neovascular Glaucoma with Ex-PRESS P-50 Miniature Glaucoma Shunt
Surgical treatment for neovascular glaucoma has evolved from cyclodestructive procedures to full-thickness filtration surgery, to trabeculectomy with antifibrosis drugs and glaucoma drainage implant surgery. The choice of a surgical approach may be influenced by several factors, including the stage of the disease. Many surgeons favor drainage implants when the disease is more advanced or when s...
متن کاملDimensional and Flow Properties of the EX-PRESS Glaucoma Drainage Device
We read with interest the article by Sheybani et al. demonstrating the assessment of fluid dynamics and flow control between the XEN 45 microfistula implant (AqueSys, Aliso Viejo, CA, USA), EX-PRESS implant (Alcon Laboratories, Inc., Fort Worth, TX, USA), and silicone tubing from a Baerveldt implant (Abbott Medical Optics, Abbott Park, IL, USA). The authors demonstrated that the Hagen-Poiseuill...
متن کامل[Tacrolimus in the treatment of atopic kerato-conjunctivitis].
1. Abraham N, Yoseff G, Michael B, Yoram E. Biocompatibility of the Ex-PRESS® miniature glaucoma drainage implant. J Glaucoma. 2003;12:275–80. 2. Gallego-Pinazo R, López-Sánchez E, Marín-Montiel J. Resultados postquirúrgicos en la cirugía combinada de glaucoma. Comparación del implante Ex-PRESS® con la trabeculectomía. Arch Soc Esp Oftalmol. 2009;84: 293–8. 3. Francis BA, Singh K, Lin SC, Hodap...
متن کاملEx-PRESS Glaucoma Filtration Device: Theory, Technique and Results
The Ex-PRESS glaucoma filtration device (Alcon Laboratories, Fort Worth, TX , USA) is designed to drain aqueous fluid from the anterior chamber to the subconjunctival space and form a filtration bleb, akin to a trabeculectomy. In this article we will review the surgical indications, preoperative evaluation, surgical techniques and postoperative considerations of this ophthalmic device. J Emmetr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 56 13 شماره
صفحات -
تاریخ انتشار 2015