Comparison of facet joint activity on 99mTc-MDP SPECT/CT with facet joint signal change on MRI with fat suppression.

نویسندگان

  • Vance T Lehman
  • Robert C Murphy
  • Louis A Schenck
  • Rickey E Carter
  • Geoffrey B Johnson
  • Amy L Kotsenas
  • Jonathan M Morris
  • Mark A Nathan
  • John T Wald
  • Timothy P Maus
چکیده

PURPOSE We compared signal change on magnetic resonance imaging (MRI) with fat suppression and bone scan activity of lumbar facet joints to determine if these two imaging findings are correlated. METHODS We retrospectively identified all patients who underwent imaging of the lumbar spine for pain evaluation using both technetium-99m methylene disphosphonate single-photon emission computed tomography/computed tomography (99mTc-MDP SPECT/CT) and MRI with at least one fat-suppressed T2- or T1-weighted sequence with gadolinium enhancement within a 180-day interval, at our institution between 1 January 2008 and 19 February 2013. Facet joint activity on 99mTc-MDP SPECT/CT and peri-facet signal change on MRI were rated as normal or increased. Agreement between the two examination types were determined with the κ and prevalence-adjusted bias-adjusted κ (PABAK) statistics. RESULTS This study included 60 patients (28 male, 47%), with a mean age of 49±19.7 years (range, 12-93 years). The κ value indicated no agreement between 99mTc-MDP SPECT/CT and MRI (κ=-0.026; 95% confidence interval: -0.051, 0.000). The PABAK values were fair to high at each spinal level, which suggests that relatively low disease prevalence lowered the κ values. Together, the κ and PABAK values indicate that there is some degree of intermodality agreement, but that it is not consistent. CONCLUSION Overall, facet joint signal change on fat-suppressed MRI did not always correlate with increased 99mTc-MDP SPECT/CT activity. MRI and 99mTc-MDP SPECT/CT for facet joint evaluation should not be considered interchangeable examinations in clinical practice or research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-phase 99mTc-MDP bone scan in a case of pigment villonodular synovitis

Pigment villondular synovitis (PVNS) is a rare synovial condition. The nature of this disorder is usually characterized as benign; however, malignant transformation has also been reported. MRI is the diagnostic modality of choice in evaluating this entity, revealing low T1 and T2 weighted signals and blooming artifact on gradient echo sequences.  Three-phase 99mTc-MDP bone scan has b...

متن کامل

Frequency of discordance between facet joint activity on technetium Tc99m methylene diphosphonate SPECT/CT and selection for percutaneous treatment at a large multispecialty institution.

BACKGROUND AND PURPOSE The clinical impact of facet joint bone scan activity is not fully understood. The hypothesis of this study is that facet joints targeted for percutaneous treatment in clinical practice differ from those with reported activity on technetium Tc99m methylene diphosphonate SPECT/CT. MATERIALS AND METHODS All patients with a technetium Tc99m methylene diphosphonate SPECT/CT...

متن کامل

Facet joint signal change on MRI at levels of acute/subacute lumbar compression fractures.

BACKGROUND AND PURPOSE The prevalence of facet joint signal change in acute/subacute lumbar vertebral body compression fractures is unknown. We hypothesized that facet joint signal change on MR imaging is more common in facet joints associated with an acute/subacute lumbar compression fracture than those associated with normal vertebral bodies or ones that have a chronic compression fracture. ...

متن کامل

The role of SPECT/CT with 99mTc-MDP image fusion to diagnose temporomandibular dysfunction.

OBJECTIVE The objective of this study was the evaluation of Single Photon Emission Computed Tomography with Technetium 99m Methylene Diphosphonate (SPECT with 99mTc-MDP) and computed tomography (CT), simultaneously acquired image in diagnosis of temporomandibular joint (TMJ) dysfunction. STUDY DESIGN A prospective study was conducted with 33 patients, 29 female and 4 male, all of then present...

متن کامل

Sinus Tarsi Syndrome: Diagnosed on 99m-Tc MDP Bone SPECT/CT

Sinus Tarsi Syndrome is a cause of chronic ankle instability and pain. MRI of the ankle has been the modality of choice for diagnosing the condition. However, SPECT-CT offers an alternate modality for diagnosing and evaluation of the condition. We present the case of a footballer who was suffering from chronic right leg pain despite receiving physiotherapy. He was being managed as a case of a c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 22 3  شماره 

صفحات  -

تاریخ انتشار 2016