Prediction of fluid responsiveness using a non-invasive cardiac output monitor in children undergoing cardiac surgery.
نویسندگان
چکیده
BACKGROUND This study evaluated the ability of a non-invasive cardiac output monitoring device (NICOM) to predict fluid responsiveness in paediatric patients undergoing cardiac surgery. METHODS Children aged <5 yr undergoing congenital heart surgery were included. Once the sternum had been closed after repair of the congenital heart defect, 10 ml kg(-1) colloid solution was administered for volume expansion. Transoesophageal echocardiography (TOE) was performed to measure stroke volume (SV) and respiratory variation in aortic blood flow peak velocity (ΔV(peak)) before and after volume expansion. Haemodynamic and NICOM variables, including SV(NICOM), stroke volume variance (SVV(NICOM)), cardiac index (CI(NICOM)), and percentage change in thoracic fluid content compared with baseline (TFCd0%), were also recorded. Patients in whom the stroke volume index (SVI), measured using TOE, increased by >15% were defined as fluid responders. RESULTS Twenty-nine patients were included (13 responders and 16 non-responders). Before volume expansion, only ΔV(peak) differed between groups (P=0.036). The SVV(NICOM), HR, and central venous pressure did not predict fluid responsiveness, but ΔV(peak) did. The CI(NICOM) was not correlated with CI(TOE) (r=0.107, P=0.43). Using Bland-Altman analysis, the mean bias between CI(TOE) and CI(NICOM) was 0.89 litre min(-1) m(-2), with a precision of 1.14 litre min(-1) m(-2). Trending ability of NICOM for SVI and CI was poor when TOE was a reference method. CONCLUSIONS The SVV(NICOM) did not predict fluid responsiveness in paediatric patients during cardiac surgery. In addition, there was no correlation between CI(TOE) and CI(NICOM). Fluid management guided by NICOM should be performed carefully. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov NCT01996956.
منابع مشابه
Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients
BACKGROUND Left ventricular stroke area by transoesophageal echocardiographic automated border detection has been shown to be strongly correlated to left ventricular stroke volume. Respiratory variations in left ventricular stroke volume or its surrogates are good predictors of fluid responsiveness in mechanically ventilated patients. We hypothesised that respiratory variations in left ventricu...
متن کاملCorrelation of intraoperative renal near infrared spectroscopy with the development of acute kidney injury in adult patients undergoing cardiac surgery using cardiopulmonary bypass
Introduction: The present study aimed to correlate renal oximetry near-infrared spectroscopy (NIRS) values with conventional non-invasive biomarkers for the early detection of acute kidney injury (AKI) in adult patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). Accordingly, renal NIRS can be employed as a trending device for the prevention of AKI developmen...
متن کاملA comparison of the non-invasive ultrasonic cardiac output monitor (USCOM) with the oesophageal Doppler monitor during major abdominal surgery.
BACKGROUND Perioperative interventions, targeted to increase global blood flow defined by explicit measured goals, reduce postoperative complications. Consequently, reliable non-invasive estimation of the cardiac output could have far-reaching benefit. METHODS This study compared a non-invasive Doppler device - the ultrasonic cardiac output monitor (USCOM) - with the oesophageal Doppler monit...
متن کاملGoal-Directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: A pilot study.
BACKGROUND Goal directed fluid therapy (GDFT) has been shown to improve outcomes in moderate to high-risk surgery. However, most of the present GDFT protocols based on cardiac output optimization use invasive devices and the protocols may require significant practitioner attention and intervention to apply them accurately. The aim of this prospective pilot study was to evaluate the clinical fea...
متن کاملCurrent practice in hemodynamic monitoring and management in high-risk surgery patients: a national survey of Korean anesthesiologists
BACKGROUND Hemodynamic optimization improves postoperative outcomes in high-risk surgery patients. The monitoring of cardiac output (CO) and dynamic parameters of fluid responsiveness can guide hemodynamic optimization. We conducted a survey to assess the current hemodynamic monitoring and management practices of Korean anesthesiologists during high-risk surgery. METHODS E-mails containing a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 115 1 شماره
صفحات -
تاریخ انتشار 2015