Automated system for infrared spectrometric analysis for total CO2 of plasma contained in capillary tubes.

نویسندگان

  • B E Rabinow
  • A Geisel
  • L E Webb
  • S Natelson
چکیده

We describe how to assay plasma total CO2 automatically, discretely, and highly specifically by infrared absorption spectrometry. Plasma, 50 mul, is sampled in disposable capillaries and inserted into a block wherein the specimens are protected from exposure to air. A sequencer advances the block and signals a dispenser to flush the sample into a reaction vessel with 2.6 ml fo 50 mmol/liter H2SO4. After 24 s of incubation, the evolved CO2 is swept into a 1-meter infrared gas cell by a stream of nitrogen. A recorder displays the resulting peak in absorbance units. Operation of all valves controlling gas and liquid flow is regulated by the sequencer. In the present version, the time required for analysis of one sample is 65 s. The sample size may be reduced by at least 10-fold and the time sequence accelerated to assay 70-80 specimens per hour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost Function Modelling for Semi-automated SC, RTG and Automated and Semi-automated RMG Container Yard Operating Systems

This study analyses the concept of cost functions for semi-automated Straddle Carrier (SC), Rubber Tyred Gantry (RTG) and automated Rail Mounted Gantry (RMG) container yard operating cranes. It develops a generic cost based model for a pair-wise comparison, analysis and evaluation of economic efficiency and effectiveness of container yard equipment to be used for decision-making by terminal pla...

متن کامل

A Biomechanical Approach for the Study of Deformation of Red Cells in Narrow Capillaries

This model focuses on the behavior of capillary-tissue fluid exchange system when the diameter of the capillary is less than that of red cell. In vivo and in vitro observations indicate that the width of the gap between the red cell and the vessel wall is generally small compared to the radius of the capillary for a single file flow of red cell in narrow vessel, particularly if the vessel diame...

متن کامل

Erratum to: 'A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use'.

Unfortunately, the original version of this article [1] contained errors. Two editing changes were made incorrectly which led to the resulting text containing confusing grammatical errors. On page three, the line that contains the following: Zero-degree thawed omit plasma samples were divided into two aliquots of 30 μL in 0.6 mL plastic Eppendorf tubes. Should read as: Zero-degree thawed sample...

متن کامل

Optimum driving a Z-pinch for soft X-Ray lasers

A capillary plasma z-pinch as an alternative active medium of soft X-Ray lasers was studied experimentally and theoretically. The theoretical analysis was based on the self consistent solution of the so called “snow plow” model. The dynamics of pinched plasma is determined by the capillary parameters and by the time dependence of electrical current passing through it. The current time dependenc...

متن کامل

An Improved GC Method for Rapid Analysis of Valproic Acid in Human Plasma Without Derivatization

        A simple, reproducible and rapid gas chromatographic method for precise determination of valproic acid (VPA) in human plasma has been developed. Total time for sample preparation and GC analysis is less than 45 min. After plasma protein precipitation, VPA was extracted into chloroform with suitable recovery. By using Stabilwax®<span styl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 2 PT. 1  شماره 

صفحات  -

تاریخ انتشار 1977