Construction of a Cerenkov light source.
نویسندگان
چکیده
A radiation source has been developed and implemented from Cerenkov emission that is intended to provide an intense continuum from the infrared to 600 A. Parasitic use of the primary electron beam at the Stanford Linear Accelerator Center (SLAC) together with a novel optical geometry for light collection can give a focused and tunable ultraviolet beam with 10(4) kW/m(2)sr brightness, 10(-2) spectral purity, and with the pulsed, 5 ps time structure of the SLAC electron beam. Measurements of emission characteristics in the visible part of the spectrum correlate closely with the predicted performance.
منابع مشابه
Ultrahigh-resolution Cerenkov-light imaging system for positron radionuclides: potential applications and limitations
OBJECTIVE Cerenkov-light imaging provides inherently high resolution because the light is emitted near the positron radionuclide. However, the magnitude for the high spatial resolution of Cerenkov-light imaging is unclear. Its potential molecular imaging applications also remain unclear. We developed an ultrahigh-resolution Cerenkov-light imaging system, measured its spatial resolution, and exp...
متن کاملFirst Results from the BELLE DIRC Prototype
The DIRC (Detection of Internally Reflected Cerenkov light) is a new type of ring imaging Cerenkov detector, which detects images from Cerenkov light produced in precisely machined quartz bars. The Cerenkov images are transported along several meters of bar to the edge of the detector where they are proximity focussed unto an array of conventional photomultiplier tubes. Results from a prototype...
متن کاملCerenkov imaging - a new modality for molecular imaging.
Cerenkov luminescence imaging (CLI) is an emerging hybrid modality that utilizes the light emission from many commonly used medical isotopes. Cerenkov radiation (CR) is produced when charged particles travel through a dielectric medium faster than the speed of light in that medium. First described in detail nearly 100 years ago, CR has only recently applied for biomedical imaging purposes. The ...
متن کاملDevelopment of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect
The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filte...
متن کاملar X iv : p hy si cs / 0 31 10 44 10 N ov 2 00 3 MODELING AND STUDY OF THE CERENKOV EFFECT
The studies realized in INRNE (Institute for Nuclear Research and Nuclear Energy) particulary in cosmic rays detection and construction of Muonic Cerenkov Telescope in University of Blagoevgrad [1] shows the need to develop a theoretical model based on observed phenomenon and to refine it for the detection system optimisation. The effect was introduced in EGS4 [2] code system. The first simulat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 50 4 شماره
صفحات -
تاریخ انتشار 1979