An integrated small-animal ventilator and recycling system for small-animal hyperpolarized gas MRI

نویسندگان

  • J. C. Nouls
  • M. Fanarjian
چکیده

Introduction Hyperpolarized (HP) gas MRI in small animals is challenging and generally requires a dedicated ventilator system. Moreover, the use of expensive rare isotopes such as He and Xe make it desirable to minimize cost by recycling these gases after they have been used for imaging. We present a constantvolume ventilator that offers precise control of gas delivery, permits highresolution imaging, and captures the exhaled mixture containing He or Xe. The captured gas is then compressed by a piston and stored in a cylinder to be sent for re-purification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mixing oxygen with hyperpolarized (3)He for small-animal lung studies.

Hyperpolarized helium (HP (3)He) is useful for direct MR imaging of the gas spaces of small animal lungs. Previously, breaths of 100% HP (3)He were alternated with breaths of air to maximize helium signal in the lungs and to minimize the depolarizing effects of O(2). However, for high-resolution imaging requiring many HP (3)He breaths (hundreds) and for pulmonary disease studies, a method was n...

متن کامل

Thermoeconomic comparison between the performance of small-scale internal combustion engines and gas turbines integrated with a biomass gasifier

Recently, many countries have paid substantial attention to power generation from biomass gasification, particularly through small-scale plants. A number of power plant models have been suggested and analyzed; however, certainly, desirable configurations have not been identified yet. Moreover, their performances are ordinarily difficult to compare, especially owing to the fact that working ...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

Measurement of Gas Flow and Oxygenation in Small Animal Lungs Using Hyperpolarized Gas

Introduction: In contrast to most proton MRI, T1 measurements of hyperpolarized gas in the lung are particularly straightforward to interpret. This is because the dominant source of relaxation arises from a single source: collisions with paramagnetic oxygen molecules. Several investigators have used this property to determine the regional oxygen concentrations that have been shown to correspond...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009