Memory plastics for prosthetic and orthotic applications.
نویسندگان
چکیده
Shrink forming prosthetic sockets from memory plastics offers several advantages over existing techniques. The manual skill requirement is reduced relative to drapeforming flat sheet while compared with the Rapidform process, the requirement for a purpose built vacuum forming machine is eliminated. Two methods for producing thermoplastic sockets from heat shrinkable preforms are described. One uses established heat shrink technology and crosslinked thermoplastics. The second based on blowmoulding simplifies preform manufacture relative to existing techniques by reducing it to a single stage operation. Shrink formed sockets have been produced for three application areas concerned with the lower limb namely load bearing sockets, flexible ISNY type and rigid transparent check sockets. Static testing has demonstrated the ability of shrink formed, load bearing sockets to surpass Philadelphia Static Load Levels (ISPO, 1978) while fatigue testing has indicated a capability for long service life.
منابع مشابه
Experiences of providing prosthetic and orthotic services in Sierra Leone--the local staff's perspective.
UNLABELLED In Sierra Leone, West Africa, there are many people with disabilities in need of rehabilitation services after a long civil war. PURPOSE The aim of this qualitative study was to explore the experiences of prosthetic and orthotic service delivery in Sierra Leone from the local staff's perspective. METHOD Fifteen prosthetic and orthotic technicians working at all the rehabilitation...
متن کاملThe Organisation of Chapters
Electromyography (EMG) is a procedure for evaluating and recording the electrical activity produced by skeletal muscles. EMG has several clinical and prosthetic applications, which include the diagnosis of neuromuscular problems, biomechanical and motor control deficits, and other functional disorders. Moreover, it can be used as a control signal for interfacing with orthotic and/or prosthetic ...
متن کاملMyoelectric control of prosthetic hands: state-of-the-art review
Myoelectric signals (MES) have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices...
متن کاملCompression testing of foamed plastics and rubbers for use as orthotic show insoles.
Thirty-one materials have been tested in compression in order to generate the stress (force per unit of cross-sectional area) versus strain (deformation) behaviour, for the purpose of assessing the suitability of various foamed plastics and rubbers as shoe insole materials. It was found that the materials could be classified into three distinct categories (very stiff, moderately deformable and ...
متن کاملAmputees and their prostheses.
1 Final report of the Facility Case Record Study. 2 Formerly Professional Assistant, Committee on Prosthetic-Orthotic Education. 3 Executive Secretary, Committee on ProstheticOrthotic Education, Division of Medical Sciences, National Academy of Sciences—National Research Council, Washington, D. C. 4 Professor of Orthopaedic Surgery, Duke University; Chairman, Subcommittee on Prosthetics Clinica...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Prosthetics and orthotics international
دوره 12 3 شماره
صفحات -
تاریخ انتشار 1988