Ultrasonographically guided peripheral intravenous cannulation in emergency department patients with difficult intravenous access: a randomized trial.
نویسندگان
چکیده
STUDY OBJECTIVE We seek to compare ultrasonographically guided peripheral intravenous access to a non-ultrasonographically guided method in a randomized trial of emergency department patients with difficult intravenous access. METHODS A prospective cohort of patients with difficult intravenous access was established. Patients were randomized to 2 groups: (1) intravenous access obtained through an ultrasonographically guided technique or (2) intravenous access obtained through non-ultrasonographically guided methods. Outcomes measured were number of attempts after enrollment, time to cannulation from enrollment, and patient satisfaction. Groups were compared with nonparametric analysis. RESULTS Fifty-nine patients were randomized. Twenty-eight patients were randomized to the ultrasonography group and 31 to the no ultrasonography group. A median of 2 further intravenous attempts was required in each group before successful cannulation, corresponding to a difference of 0 attempts (95% confidence interval [CI] 0 to 1 attempts). Time to cannulation showed a median of 39 minutes in the ultrasonography group compared with 26 minutes for the no ultrasonography group, giving a median increase of 13 minutes for the ultrasonographically guided group (95% CI -5 to 28 minutes). Patients in the ultrasonography group had a median Likert satisfaction score of 8 compared with 7 for the no ultrasonography group, giving a median increase of 1 on this scale in the ultrasonography group (95% CI 0 to 2). CONCLUSION Ultrasonographically guided peripheral intravenous cannulation did not decrease the number of attempts or the time to successful catheterization, nor did it improve patient satisfaction compared with the group that did not use ultrasonography. Superiority of ultrasonographically guided peripheral intravenous cannulation is not supported by this study.
منابع مشابه
Ultrasound-guided brachial and basilic vein cannulation in emergency department patients with difficult intravenous access.
STUDY OBJECTIVE Emergency department patients who require intravenous access but lack peripheral intravenous sites frequently require central line placement. Blind percutaneous brachial vein cannulation has been proposed as an alternative in these patients but is associated with high failure and complication rates. We evaluated an ultrasound-guided approach to percutaneous deep brachial vein or...
متن کاملUltrasonographically guided peripheral intravenous cannulation of children and adults: a systematic review and meta-analysis.
STUDY OBJECTIVE Peripheral intravenous cannulation is procedurally challenging and painful. We perform a systematic review to evaluate ultrasonographic guidance as an aid to peripheral intravenous cannulation. METHODS We searched MEDLINE, Cochrane Central Register of Controlled Trials, EMBASE, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Web of Science, ClinicalTrials.go...
متن کاملUltrasonographically guided insertion of a 15-cm catheter into the deep brachial or basilic vein in patients with difficult intravenous access.
STUDY OBJECTIVE Standard length (3 to 5 cm) intravenous catheters in the deep brachial or basilic vein tend to dislodge prematurely. We assess the safety and longevity of a 15-cm catheter inserted in these veins by a novel ultrasonographically guided technique. METHODS This is a prospective cohort study conducted in an urban teaching emergency department (ED). Adult subjects were enrolled if ...
متن کاملIII. Tidal volume measurement: OK for science, but too difficult for a workstation standard?
assisted intravenous catheter placement in a pediatric emergency department. Acad Emerg Med 2011; 18: 966–71 9 Kim M, Park J, Rhee N, et al. Efficacy of VeinViewer in pediatric peripheral intravenous access: a randomized controlled trial. Eur J Pediatr 2012; 171: 1121–5 10 Sanchez-Morago G, Sanchez Coello M, Villafranca Casanoves A, Cantero Almena J, Migallon Buitrago M, Carrero Caballero M. Vi...
متن کاملUltrasound-guided “short” midline catheters for difficult venous access in the emergency department: a retrospective analysis
BACKGROUND Acutely ill patients admitted to the emergency department (ED) constantly require at least one fast and reliable peripheral intravenous (PIV) access. In many conditions (morbid obesity, underweight state, chronic diseases, intravenous drug abuse, adverse local conditions, etc.), PIV placement may be challenging. Ultrasound guidance is a useful tool for obtaining a peripheral intraven...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of emergency medicine
دوره 54 1 شماره
صفحات -
تاریخ انتشار 2009