The influence of mock circulation input impedance on valve acceleration during in vitro cardiac device testing.

نویسندگان

  • M Keith Sharp
  • Christopher M Richards
  • Kevin J Gillars
  • Guruprasad Giridharan
  • George M Pantalos
چکیده

For a mechanical heart valve, a strong spike in pressure during closing is associated with valve wear and erythrocyte damage; thus, for valid in vitro testing, the mock circulation system should replicate the conditions, including pressure spikes, expected in vivo. To address this issue, a study was performed to investigate how mock circulation input impedance affects valve closure dynamics. A left ventricular model with polyurethane trileaflet inflow valve and tilting disc outflow valve was connected to a Louisville mock circulation system, which incorporates 2 adjustable flow resistors and 2 compliances. In the study, 116 cases matched zero frequency modulus well (982-1147 dyn x s/cm), but higher harmonics were purposely varied. Acceleration measured at the outflow valve ring (42.4-89.4 milli-Gs) was uncorrelated with impedance error (74.1-237 dyn x s/cm relative to target impedance), but was correlated with end-systolic impedance (1082-1319 dyn x s/cm) for cases with high zero frequency modulus, which exhibited just less than full ejection. These differences demonstrate that mock circulation response affects the magnitude of the closing spike, indicating that control of this parameter is necessary for authentic testing of valves. Correlation of acceleration to end-systolic impedance was weak for low zero frequency modulus, which tended toward full or hyperejection, reinforcing common laboratory observations that valve closing also depends on ventricular operating conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous.

The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was...

متن کامل

Vasodilators in congestive heart failure.

1. Sarnoff SJ, Berglund E: Neurohemodynamics of pulmonary edema. IV. Effect of systemic vasoconstriction and subsequent vasodilation on flow and pressures in systemic and pulmonary vascular beds. Am J Physiol 170: 588, 1952 2. Imperial ES, Levy MN, Zieske H Jr: Outflow resistance as an independent determinant of cardiac performance. Circ Res 9: 1148, 1961 3. Sonnenblick EH, Downing SE: Afterloa...

متن کامل

Evaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation.

OBJECTIVE Assess a prototype inspiratory impedance threshold valve (ITV) designed to enhance vital organ circulation during standard and active compression/decompression cardiopulmonary resuscitation (CPR). BACKGROUND The ITV attaches to commonly used airway assist devices and decreases intrathoracic pressure during the decompression (chest recoil) phase of CPR by creating a vacuum within the...

متن کامل

Use of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report.

Building upon studies on the mechanism of active compression-decompression (ACD) cardiopulmonary resuscitation, a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the decompression phase of CPR. Use of this device results in a greater negative intrathoracic pressure during chest wall decompression. This leads to improved vital orga...

متن کامل

Evaluation of Pediatric Pulmonary Artery Input Impedance Using Windkessel Models and Doppler Ultrasound: in Vitro and Clinical Studies

The m pulmonary h cardiologists of chronic th facilitated th therapeutic reactivity. H vascular rea relying on qu defined as th to mean pul hemodynami compliance estimates of compliance i In cont generated tho ratio of tim represented resistance an from the im model that e case. Signifi that depict t system using models. By e prove useful dynamics an This in models to parameters o using a mock ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ASAIO journal

دوره 54 4  شماره 

صفحات  -

تاریخ انتشار 2008