ASTER/TIR onboard calibration status and user-based recalibration
نویسندگان
چکیده
Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), one of five sensors on Terra, has five bands (10 to 14) in the thermal infrared (TIR) region. These TIR bands are radiometrically calibrated by one onboard blackbody with the function of changing temperature between 270 and 340 K. In normal operation the blackbody is set up at 270 K, and a constant coefficient in a quadratic radiometric calibration equation for each detector is adjusted at that temperature before each Earth observation, but the gain coefficient cannot be adjusted at this time, while it can periodically be updated by long term calibration in which the blackbody is measured at 270, 300, 320, and 340 K. On the other hand the sensor response of all bands (particularly band 12) has been degrading since the launch, and periodical updating of the gain coefficient does not fully follow the degradation, so that the calibration error on level-1 (L1) products is often unacceptable. We therefore have developed a recalibration method which is easily applied to L1 products by a general user. By using this method, the calibration error will mostly be reduced below the level of NEDT.
منابع مشابه
Comparison Among Cross, Onboard and Vicarious Calibrations for Terra/ASTER/VNIR
Comparative study on radiometric calibration methods among onboard, cross and vicarious calibration for visible to near infrared radiometers onboard satellites is conducted. The data sources of the aforementioned three calibration methods are different and independent. Therefore, it may say that the reliable Radiometric Calibration Accuracy: RCC would be the RCC which are resemble each other tw...
متن کاملExperimental Approach of Reflectance Based Vicarious Calibration Method for Solar Reflectance Wavelength Region of Sensor Onboard Remote Sensing Satellites
Experimental approach of reflectance based vicarious calibration of solar reflectance wavelength region of mission instruments onboard remote sensing satellites is conducted. As an example, vicarious calibration of ASTER/VNIR with estimated aerosol refractive index and size distribution that depends on atmospheric conditions is discussed. Strange solution of estimated refractive index and size ...
متن کاملSuspected Plume Impingement Influence on Board Calibration System of Terra/aster/vnir Investigated through Trend Analysis on Board Calibration Data
Trend analysis of Terra/ASTER/VNIR calibration data is made for finding possible causes for degradation of radiometric calibrat ion coefficients. Two sets of photometers are equipped at just after the onboard calibration lamp and at just in front of optics en trance of the mission instrument, VNIR. Unfortunately, the later was malfunctioned 300 days after the launch so that degradation of calib...
متن کاملRegional Lithological Mapping Using ASTER-TIR Data: Case Study for the Tibetan Plateau and the Surrounding Area
The mineralogical indices the Quartz Index (QI), Carbonate Index (CI) and Mafic Index (MI) for ASTER multispectral thermal infrared (TIR) data were applied to various geological materials for regional lithological mapping on the Tibetan Plateau. Many lithological and structural features are not currently well understood in the central Tibetan Plateau, including the distribution of mafic-ultrama...
متن کاملASTER Observations of the Spectral Emissivity over New Mexico
On several days in 2000 & 2001 the Advanced Spaceborne Thermal Emission and Reflection radiometer (ASTER) on the Terra satellite obtained data over the Jornada Experimental Range test site along the Rio Grande river and the White Sand National Monument in New Mexico. ASTER has 14 channels from the visible (VNIR) through the thermal infrared (TIR) with 15 m resolution in the VNIR and 90 m in the...
متن کامل