The Influence of Lesion Location on the Diagnostic Accuracy of Adenosine-Free Coronary Pressure Wire Measurements.
نویسندگان
چکیده
OBJECTIVES This work compares the diagnostic performance of adenosine-free coronary pressure wire indices based on lesion location. BACKGROUND Several adenosine-free coronary pressure wire indices have been proposed to assess the functional significance of coronary artery lesions; however, there is a theoretical concern that lesion location and the mass of perfused myocardium may affect diagnostic performance. METHODS A total of 763 patients were prospectively enrolled from 12 institutions. Fractional flow reserve (FFR) and contrast-based FFR (cFFR) were obtained during adenosine-induced maximal hyperemia and contrast-induced submaximal hyperemia respectively, whereas the instantaneous wave-free ratio (iFR) and distal pressure/aortic pressure (Pd/Pa) were obtained at rest. Using an FFR of ≤0.80 as a reference standard, the diagnostic accuracy of each index was compared based on lesion location (left main or proximal left anterior descending artery [LM/pLAD] compared with other lesion locations). RESULTS The median FFR, cFFR, iFR, and Pd/Pa were 0.81 (interquartile range [IQR]: 0.74 to 0.87), 0.86 (IQR: 0.79 to 0.91), 0.90 (IQR: 0.85 to 0.94), and 0.92 (IQR: 0.88 to 0.95), respectively. The cFFR, iFR, and Pd/Pa were less accurate in LM/pLAD compared with other lesion locations (cFFR: 80.3% vs. 87.8%; iFR: 73.3% vs. 81.8%; Pd/Pa: 71.4% vs. 81.1%, respectively). By receiver-operating characteristics curve analysis, cFFR provided better diagnostic accuracy than resting indices regardless of lesion location (p ≤0.0001 vs. iFR and Pd/Pa for both groups). CONCLUSIONS The cFFR, iFR, and Pd/Pa are less accurate in LM/pLAD compared with other lesion locations, likely related to the larger amount of myocardium supplied by LM/pLAD. Nevertheless, cFFR provides the best diagnostic accuracy among the adenosine-free indices, regardless of lesion location.
منابع مشابه
Effect of simultaneous intracoronary guidewires on the predictive accuracy of functional parameters of coronary lesion severity.
The aim of this study was to assess the influence of a second guidewire on the diagnostic accuracy of functional parameters of coronary lesion severity. Sixty-five patients with intermediate coronary lesions underwent myocardial perfusion scintigraphy. Fractional flow reserve (FFR), coronary flow velocity reserve (CFVR), and hyperemic stenosis resistance (HSR) index (HSR = stenosis pressure gra...
متن کاملDiagnostic accuracy of combined intracoronary pressure and flow velocity information during baseline conditions: adenosine-free assessment of functional coronary lesion severity.
BACKGROUND The assessment of functional coronary lesion severity using intracoronary physiological parameters such as coronary flow velocity reserve and the more widely used fractional flow reserve relies critically on the establishment of maximal hyperemia. We evaluated the diagnostic accuracy of the stenosis resistance index during nonhyperemic conditions, baseline stenosis resistance index, ...
متن کاملFlow Visualization by Conditional Sampling of a Single X-Wire Probe in a Very Long Run Experiment
Flow visualization techniques using tracer markers such as die, smoke, hydrogen bubbles, etc., have been widely used in experimental investigations of large scale structures of a variety of flow fields. They have played an important role in understanding the physics of the coherent structures formation and evolution in the transitional as well as the turbulent regions of the flow fields. Howeve...
متن کاملInfluence of Heart Rate and Contractility on Coronary Diagnostic Parameters with Normal Microvasculature in Porcine Model
1 ABSTRACT Invasive guide-wire measurements are used to assess coronary lesion severity under clinical settings. The objective of the present research is to determine the influence of heart rate (HR) and contractility (CY) on fractional flow reserve (FFR; the ratio of distal pressure to proximal pressure at a stenotic section) and pressure drop coefficient (CDPe; the ratio of trans-stenotic pre...
متن کاملAssociation between coronary lesion severity and distal microvascular resistance in patients with coronary artery disease.
Homogeneity of microvascular resistance in different perfusion areas of the same heart is generally assumed. We investigated the effect of the severity of an epicardial stenosis on microvascular resistance in 27 patients with coronary artery disease and stable angina. All patients had an angiographically normal coronary artery, an artery with an intermediate lesion, and an artery with a severe ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 9 23 شماره
صفحات -
تاریخ انتشار 2016