Origins of Higher Poles in Quadrupole Magnets
نویسندگان
چکیده
.’ The magnetic field measurements in multipole magnetic fields, which are used to measure magnetic field parameters in the strong-focusing lenses for the Stanford two-mile linear accelerator, will be reviewed. Specifically, the theory and the measurement processes used to determine such important parameters as the magnetic center in multipoles, the length of the gradient fields, and the harmonic content in strong-focusing lenses will be described. The results of these accurate measurements will be related to the optical parameters of the multipole lenses.
منابع مشابه
منبع تغذیه مغناطیسهای حلقه افزاینده انرژی طرح چشمه نور ایران
The Iranian Light Source Facility (ILSF) booster main specifications including 250 ms ramp up, 2Hz repetition rate, and quasi-sinusoidal wave shape, up to this point have been the basis for calculations. Each family of magnets including Dipole, Quadrupole and Sextupoles will feed by individual power supply. In order to maintain constant transverse tunes and chromaticity while the beam is accele...
متن کاملطراحی، شبیهسازی و ساخت آهنربای چهارقطبی جهت همگرایی باریکه الکترونی درشتابدهنده پرقدرت صنعتی الکترون
In this paper the design and simulation of quadrupole magnets and electron beam optical of that by CST Studio code has been studied. Based on simulation result the magnetic quadrupole has been done for using in beam line of first Iranian powerful electron accelerator. For making the suitable magnetic field the effects of material and core geometry and coils current variation on quadrupole ma...
متن کاملStudy of the Magnetic Coupling between Quadrupole and Dipole Corrector Magnets for the Kek B-factory
Most of the quadrupole magnets in the KEK B-factory are accompanied by a set of vertical and horizontal dipole corrector magnets in both the LER and HER rings[1]. The typical separation between a quadrupole and a dipole corrector magnet is 202 mm, as measured from the laminated ends. This corresponds to ~3.7 (2.4) times of the bore radius of a quadrupole magnet in the arc (straight) sections. S...
متن کاملProposal for a Feasibility Study of Very Large Aperture Quadrupole Magnets’
We seek expert assistance in performing a feasibility study for quadrupole magnets with inner radius at least 80 cm, field at that radius of at least 1.5 Tesla, and field integral at that radius of at least 3 Tesla-m. These magnets would be used as the spectrometer magnets in hadron-collider experiments that emphasize relatively low transverse momentum and large angular coverage, such as studie...
متن کاملTests and Measurements of the CESR Phase III Interaction Region Superconducting Magnets
Superconducting interaction region magnets for the CESR ring have been built by industry and tested. They will allow for higher luminosity by reducing the long range beam-beam effect at the crossing point nearest to the interaction point (IP). They also provide the necessary energy flexibility needed for charm physics operation in the future. The design of these magnets places them as close as ...
متن کامل