Effect of attenuation correction on normal (99)mTc-MIBI myocardial perfusion scintigrams acquired with a hybrid SPECT/CT camera.

نویسندگان

  • Anna Płachcińska
  • Jakub Siennicki
  • Katarzyna Kovacevic-Kuśmierek
  • Małgorzata Bieńkiewicz
  • Jacek Kuśmierek
چکیده

The aim of this study was to evaluate the effect of the CT-derived attenuation correction on (99m)Tc-MIBI normal myocardial perfusion scintigrams. Rest perfusion scintigrams of patients in whom coronary artery disease was suspected, without a history or any signs in ECG of a myocardial infarction, were analysed. Patients were included in the material if their rest perfusion scintigrams were normal. This criterion was fulfilled by 61 patients (29 men and 32 women) aged between 40 and 74 (mean value 57) years, with body mass between 50 and 120 (mean value 70) kg. Tomographic reconstruction of a radionuclide study was performed with an iterative OSEM method (10 subsets, 2 iterations) sequentially without and with attenuation and scatter corrections on a dedicated Xeleris workstation, applying an ACQC tool to enable manual realignment of SPECT and CT images. SPECT studies were evaluated visually and semiquantitatively. Visual analysis of tomograms was performed with the aim of finding sites of significantly lower counts in comparison with the maximal level (in the lateral wall). Semiquantitative analysis was based on counts in 20 segments of a polar map. Attenuation correction caused a complete (in 32 of 40 - 80% of patients) or partial (in 8 of 40 - 20% of patients) filling out of all areas of lower counts in the inferior wall. However, although in the anterior wall attenuation correction caused a complete (in 11 of 35 - 31% of cases) or partial (10 of 35 - 29% of cases) filling of areas of lower counts, in 14 cases (40%) those areas remained unchanged or increased, and in 8 cases (13% of all patients) new areas of decreased counts appeared. The same was true for the apical region, in which areas of decreased counts were detected in 14 of 61 (23%) cases without attenuation correction, but after application of the correction number of apical defects, this figure grew to 22 (36%) patients. Altogether, attenuation correction reduced the total number of lower count areas from 104 to 66. Semi-quantitative analysis revealed that attenuation correction reduced nonuniformity in counts in the whole myocardium - the mean difference between segment with maximum counts and values in all segments was reduced from 17.5 +/- +/- 12% to 11.0 +/- 10.3% (p < 0.0001) in male patients, and in female patients, from 11.5 +/- 9% to 10.5 +/- 8.6%, thus equalling non-uniformities in myocardial scintigrams of both sexes. Misalignment of CT and SPECT studies was observed in 17 (28%) patients but only in 2 (3% of all patients) patients did CT realignment evidently change the attenuation corrected scintigrams. Although attenuation correction can cause artefacts, its use is justified by the reduction of the total number of areas of lower counts and the improvement of uniformity of images of normally perfused myocardium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Gated 99mTc-MIBI myocardial perfusion SPECT in patients with right bundle branch block but without evidence of coronary artery disease

Introduction: We aimed to investigate the effect of right bundle branch block (RBBB) on perfusion and functional parameters in dipyridamole stress/rest Tc99m-MIBI gated myocardial perfusion SPECT (GSPECT) which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 73 patients with low pre-test likelihood of coronary artery disease in two groups:  38 patients wit...

متن کامل

Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom

Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuclear medicine review. Central & Eastern Europe

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2008