On-line compensation of dose changes caused by tumor motion
نویسندگان
چکیده
Treating tumors that are subject to intrafractional motion (e.g. lung tumors) with scanned particle beams leads to deterioration of the deposited dose distributions. One possible technique to mitigate motion effects is beam tracking [1]. In case of rotational motion the beam path and thereby the dose deposition in the plateau region proximal of the Bragg peak position changes despite adaptation of the Bragg peak position by tracking (see Figure 1). Adequate on-line compensation of these effects will be required for tumors that rotate remarkably during respiration. [2].
منابع مشابه
Upgrade of the therapy control system for on-line dose compensation
Beam tracking is the potentially most conformal motion mitigation technique in scanned ion beam therapy. For translational motion, beam tracking has been shown to be feasible precisely [1]. If rotational or even deformable motion is present, dose deposition changes even if beam tracking is applied because beam tracking adapts the Bragg peak position only. Dose deposition to other regions, mainl...
متن کاملAutomatic detection of liver tumor motion by fluoroscopy images
Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...
متن کاملA feasibility study of dynamic verification for tumor target delineation and dose delivery using a six degrees of freedom motion phantom
Background: The dynamic phantom is one of the best tools to study the impact of motion on tumor target delineation and absorbed dose verification during dose delivery. Materials and Methods: this study, a 6-DOF (degrees of freedom) phantom was designed following the stacked serial kinematics and assembled by six commercial motion stages to generate 6-DOF motion, which were RotX (pitch, around X...
متن کاملA quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates
Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...
متن کاملInvestigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study
Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...