Calculation of Blood Dose in Patients Treated With 131I Using MIRD, Imaging, and Blood Sampling Methods

نویسندگان

  • Elham Piruzan
  • Mahdi Haghighatafshar
  • Reza Faghihi
  • Seyed Mohammad Entezarmahdi
چکیده

Radioiodine therapy is known as the most effective treatment of differentiated thyroid carcinoma (DTC) to ablate remnant thyroid tissue after surgery. In patients with DTC treated with radioiodine, internal radiation dosimetry of radioiodine is useful for radiation risk assessment. The aim of this study is to describe a method to estimate the absorbed dose to the blood using medical internal radiation dosimetry methods. In this study, 23 patients with DTC with different administrated activities, 3.7, 4.62, and 5.55 GBq after thyroidectomy, were randomly selected. Blood dosimetry of treated patients was performed with external whole body counting using a dual-head gamma camera imaging device and also with blood sample activity measurements using a dose calibrator. Absorbed dose to the blood was measured at 2, 6, 12, 24, 48, and 96 hours after the administration of radioiodine with the 2 methods. Based on the results of whole body counting and blood sample activity dose rate measurements, 96 hours after administration of 3.7, 4.62, and 5.55 GBq of radioiodine, absorbed doses to patients' blood were 0.65 ± 0.20, 0.67 ± 0.18, 0.79 ± 0.51 Gy, respectively. Increasing radioiodine activity from 3.7 to 5.55 GBq increased blood dose significantly, while there was no significant difference in blood dose between radioiodine dosages of 3.7 and 4.62 GBq. Our results revealed a significant correlation between the blood absorbed dose and blood sample activity and between the blood absorbed dose and whole body counts 24 to 48 hours after the administration of radioiodine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of organ doses in radioiodine therapy using medical internal radiation dosimetry (MIRD) method

Background: Radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. The scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (MIRD) method. At the end, the results of MIRD calculations were compared with thermoluminescent dosimeter (TLD...

متن کامل

Can previous thyroid scan induce cytogenetic radioadaptive response in patients treated by radioiodine for hyperthyroidism?

Background: Induction of radioadaptive responses in cells pretreated with a low dose radiation before exposure to a high dose is well documented by many investigators. The aim of this study is to determine the frequency of chromosomal aberration in peripheral blood lymphocytes of patients treated by radioiodine (131I) for hyperthyroidism, with or without previous thyroid scan with 99mTc. Materi...

متن کامل

Dosimetry of Nano-Radio-Ytterbium Therapy by MIRD and MCNP methods for humans’ organs

Introduction: Nano radio-pharmaceutical therapy (NRPT) is a new method for solid tumor therapy. The treatment uses a radioactive form of radionuclide encapsulated in the poly amido amine dendrimers. The poly (amidoamine) (PAMAM) dendrimers have attracted attentions for cancer treatment by their characteristics of targeted drug carriers, delivery agents, and imaging agents in hu...

متن کامل

Comparison of Iodine-131 Absorbed Dose and Technetium-99m in Thyroid Scanning Using the MCNPX Simulation Code in the ORNL-MIRD Phantom

Thyroid scanning is performed to examine the thyroid gland disorders using 99mTc. Through the obtained images can evaluate the size of the thyroid gland, the amount of its removal compared with the salivary gland, examine the thyroid nodules and its performance impairments. According to the scan view, it is possible to differentiate between hot and cold thyroid nodules that need different thera...

متن کامل

Radioiodine (131-I) treatment for Graves’ disease: Geant4 Monte Carlo simulation for patient personalized dose estimation

Background: Reliable estimation of radiation-absorbed dose is necessary to evaluate the benefits and the risks of radiopharmaceuticals used for diagnostic or therapeutic purposes in nuclear medicine. Materiel and Methods: This study included 47 patients treated with iodine-131 for Graves’ disease. A comparative study between Geant4 Monte Carlo simulation and MIRD formalism was carried out to ev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016