High-resolution renal MRA: comparison of image quality and vessel depiction with different parallel imaging acceleration factors.

نویسندگان

  • Henrik J Michaely
  • Karin A Herrmann
  • Harald Kramer
  • Olaf Dietrich
  • Gerhard Laub
  • Maximilian F Reiser
  • Stefan O Schoenberg
چکیده

PURPOSE To investigate the image quality and vessel depiction of renal MRA with integrated parallel imaging techniques (iPAT) using acceleration factors of 2 and 3. MATERIALS AND METHODS In this prospective study renal MRA was performed on 14 and 12 patients with acceleration factors of 3 and 2, respectively. For the MRA a 3D-GRE sequence with an acquired spatial resolution of 0.9 x 0.8 x 1.0 mm(3) was applied (TR/TE = 3.79 msec/1.39 msec, FOV = 400 mm x 320 mm, acquired matrix = 512 x 384, flip angle = 25 degrees) on a 32-channel 1.5T MR scanner. The acquisition time was 26 seconds with iPAT 2, and 19 seconds with iPAT3. All parameters other than acquisition time and acceleration factor were kept constant. To assess the signal-to-noise ratio (SNR) we performed repetitive phantom measurements using iPAT 2 and 3. The images were rated by two radiologists in terms of noise, artifacts, and the quality of vessel depiction for the proximal, segmental, and subsegmental renal artery. A Mann-Whitney U-test and kappa-test were used for statistical analysis. RESULTS SNR decreased significantly with iPAT 3 in the phantom measurements. The two readers found no difference in noise, but significantly fewer artifacts with iPAT 3. The depiction of segmental vessels was significantly better for both readers with iPAT 3, and the subsegmental vessels were rated significantly better by one reader. iPAT 3 also resulted in a better interreader agreement. CONCLUSION The use of iPAT 3 for renal MRA enables a better depiction of the distal parts of the renal artery. The decrease in SNR is not diagnostically impairing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly Accelerated Contrast-Enhanced MR Angiography using Ghost Imaging

Introduction: Contrast-enhanced MRA (CE-MRA) is a well-established methodology that accurately depicts vessel morphology in multiple vascular territories. In order to minimize the signal contribution from background tissues, a precontrast data set is typically subtracted from the post-contrast data set. Parallel acceleration techniques such as GRAPPA and SENSE are routinely used to improve spat...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

Nonconvex Compressive Sensing with Parallel Imaging for Highly Accelerated 4D CE-MRA

Overview: CAPR [1,2] is a state-of-the-art SENSE-type [3] parallel acquisition paradigm for Cartesian 3D time-resolved (4D) contrast-enhanced MR angiography (CE-MRA) that combines high-resolution calibration scans, custom coil arrays, and a flexible undersampled 3DFT sequence to generate diagnostic-quality images at acceleration factors of 10-40x. CAPR images are typically reconstructed online ...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

High spatial and temporal resolution dynamic contrast-enhanced magnetic resonance angiography (CE-MRA) using compressed sensing with magnitude image subtraction

PURPOSE We propose a compressed-sensing (CS) technique based on magnitude image subtraction for high spatial and temporal resolution dynamic contrast-enhanced MR angiography (CE-MRA). METHODS Our technique integrates the magnitude difference image into the CS reconstruction to promote subtraction sparsity. Fully sampled Cartesian 3D CE-MRA datasets from 6 volunteers were retrospectively under...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2006