Sensitivity Analysis on Turbine-Generator Shaft Torque in 154kV Transmission System
نویسندگان
چکیده
The torsional stress is caused by interaction between electrical transient air-gap torque by electrical disturbances and mechanical torque of turbine-generator shaft system. If a transient shaft torque exceeds a certain threshold, the loss of fatigue life occurs and in the end it is possible to happen shaft failure. This paper discusses that which factors can damage to turbine-generator shaft and how those factors cause transient shaft torque. For the study, we conducted sensitivity analysis for turbine-generator shaft system to assess torsional stress. We carried out various simulations by using ElectroMagnetic Transient Program (EMTP) based on actual Korea 154kV transmission system. Based on simulation results, this paper provides Zone of Vulnerability (ZoV) considering fault types and locations. Therefore, system operators need to study those factors that may result in torsional stress in detail, especially within ZoV.
منابع مشابه
Development of a Leader-End Reclosing Algorithm Considering Turbine-Generator Shaft Torque
High-speed auto-reclosing is used in power system protection schemes to ensure the stability and reliability of the transmission system; leader-follower auto-reclosing is one scheme type that is widely used. However, when a leader-follower reclosing scheme responds to a permanent fault that affects a transmission line in the proximity of a generation plant, the reclosing directly impacts the tu...
متن کاملEffect of Different Turbine-generator Shaft Models on the Subsynchronous Resonance Phenomenon in the Double Cage Induction Generator Based Wind Farm
This paper focuses on the turbine-generator shaft models of double-cage Induction Generator (IG) based wind farm and its influence on the sub-synchronous resonance phenomenon. For this purpose, six different shaft models as 6-mass, 4-mass, 3-mass I, 3-mass II, 2-mass and 1-mass models are considered for double-cage IG wind-turbine. By using the linear modal analysis method, the effects of the d...
متن کاملA Novel Wind Turbine Concept Based on an Electromagnetic Coupler and the Study of Its Fault Ride-through Capability
This paper presents a novel type of variable speed wind turbine with a new drive train different from the variable speed wind turbine commonly used nowadays. In this concept, a synchronous generator is directly coupled with the grid, therefore, the wind turbine transient overload capability and grid voltage support capability can be significantly improved. An electromagnetic coupling speed regu...
متن کاملOptimal Torque Control of PMSG-based Stand-Alone Wind Turbine with Energy Storage System
In this paper optimal torque control (OTC) of stand-alone variable-speed small-scale wind turbine equipped with a permanent magnet synchronous generator and a switch- mode rectifier is presented. It is shown that with OTC method in standalone configuration, power coefficient could be reached to its maximum possible value, i.e. 0.48. An appropriate control algorithm based on turbine characterist...
متن کاملAnalysis and Design of a Permanent-Magnet Outer-Rotor Synchronous Generator for a Direct-Drive Vertical-Axis Wind Turbine
In Permanent-Magnet Synchronous Generators (PMSGs) the reduction of cogging torque is one of the most important problems in their performance and evaluation. In this paper, at first, a direct-drive vertical-axis wind turbine is chosen. According to its nominal value operational point, necessary parameters for the generator is extracted. Due to an analytical method, four generators with differen...
متن کامل