OBJECTIVE Our objective was to assess potential causative factors of stent-graft collapse after thoracic endovascular aortic repair. METHODS We retrospectively reviewed clinical data and preoperative and postoperative computed tomographic scans of patients with thoracic stent-graft collapse in 2 French departments of vascular surgery. Aortic arch angulation, length of the lack of device wall apposition, proximal aortic diameter, and percentage of oversizing were assessed. RESULTS We report 4 cases of stent-graft collapse among 285 patients treated by thoracic endovascular aortic repair. All 4 patients were treated with the TAG stent graft. Only one of the patients had a symptomatic collapse: he was treated by stent-graft explantation and open repair. Endovascular management was performed in 3 of the 4 patients. None of the patients died. Lack of device wall apposition and acute aortic arch angle (range 92 degrees-118 degrees ) were observed in all 4 patients. Oversizing over 20% was observed in 3 patients. CONCLUSION This stent-graft-related complication seems related to poor apposition of the stent grafts in the highly angulated aortic arch. Excessive stent-graft oversizing could be an additional causative factor. Accurate assessment of aortic arch anatomic features, as well as the choice and sizing of the device, may prevent this complication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Late lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm

We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.

متن کامل

Endograft collapse following endovascular repair of traumatic aortic injury.

The advent of endovascular treatment of traumatic thoracic aortic injuries offers a valuable, minimally invasive alternative to open surgical repair. However, there are limitations of the current endovascular stent graft technology for this group of patients. After endovascular repair meticulous follow-up is required with a high index of suspicion for potential complications including the letha...

متن کامل

Delayed endovascular treatment of descending aorta stent graft collapse in a patient treated for post- traumatic aortic rupture: a case report

BACKGROUND We report a case of delayed endovascular correction of graft collapse occurred after emergent Thoracic Endovascular Aortic Repair (TEVAR) for traumatic aortic isthmus rupture. CASE PRESENTATION In 7th post-operative day after emergent TEVAR for traumatic aortic isthmus rupture (Gore TAG® 28-150), a partial collapse of the endoprosthesis at the descending tract occurred, with no sig...

متن کامل

Observations on the failure of stent-grafts in the aortic arch.

INTRODUCTION The results of endovascular stent-grafts in the abdominal aorta and descending thoracic aorta have been encouraging. Expanding the use of thoracic stent-grafts in to the aortic arch has been associated with increasing numbers of complications. Recently isolated cases of stent-graft collapse have been reported. METHODS This was a multi-centre European case series. Data was collect...

متن کامل

Emergency endovascular stent-graft repair for thoracic aortic injury.

We report a case of emergency endovascular stent-graft repair of a traumatic false aneurysm of the thoracic aorta. Thoracotomy was relatively contraindicated because the patient also sustained incomplete spinal injury, He recovered fully from both chest and spinal injuries, and remains without evidence of complications related to the stent-graft 18 months after the injury.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 139 5  شماره 

صفحات  -

تاریخ انتشار 2010