Cerebral near infrared spectroscopy: emitter-detector separation must be increased.
نویسندگان
چکیده
We have compared the effect of increasing optode separation (range 0.7-5.5 cm) on the sensitivity of near infrared spectroscopy (NIRS) to discrete reductions in scalp and cerebral oxygenation in 10 healthy men (mean age 32, range 26-39 yr) using multichannel NIRS. During cerebral oligaemia (a mean reduction in middle cerebral artery flow velocity of 47%) induced by a mean reduction in end-tidal PCO2 of 2.4 kPa, the decrease in oxyhaemoglobin detected by NIRS became significantly greater with increasing optode separation (P < 0.0001). In response to scalp hyperaemia induced by inflation and release of a pneumatic scalp tourniquet, increases in oxyhaemoglobin became significantly smaller with increasing optode separation (P < 0.0002). These results are consistent with theoretical models of the behaviour of NIR light in the adult head and support the concept of using multi-detector NIRS to separate intra- and extracranial NIR signal changes. However, the emitter-detector separation used by currently available cerebral oximeters is not large enough to provide optimal spatial resolution.
منابع مشابه
Changes in tissue oxyhaemoglobin concentration measured using multichannel near infrared spectroscopy during internal carotid angiography.
OBJECTIVE To develop an in vivo model for testing spatially resolved spectroscopy and quantified near infrared spectroscopy (NIRS) cerebral blood flow measurements. METHOD Multiple detector NIRS has been used to study changes in tissue oxyhaemoglobin (O2Hb) concentration during selective internal carotid angiography. A significant reduction in O2Hb occurred in tissue interrogated by detectors...
متن کاملDetection of delayed cerebral ischemia (DCI) in subarachnoid haemorrhage applying near-infrared spectroscopy: elimination of the extracerebral signal by transcutaneous and intraparenchymatous measurements in parallel.
BACKGROUND Detection of delayed cerebral ischemia (DCI) in high-grade subarachnoid haemorrhage (SAH) is an unsolved issue. Conventional near-infrared spectroscopy (NIRS) with optodes applied over the skin is controversial because the NIRS signal is contaminated by extracerebral tissue. The objective is to quantify and subtract the contribution from extracerebral tissue from the signal by using ...
متن کاملQuantitative Comparison of Analytical solution and Finite Element Method for investigation of Near-Infrared Light Propagation in Brain Tissue Model
Introduction: Functional Near-Infrared Spectroscopy (fNIRS) is an imaging method in which light source and detector are installed on the head; consequently, re-emission of light from human skin contains information about cerebral hemodynamic alteration. The spatial probability distribution profile of photons penetrating tissue at a source spot, scattering into the tissue, and being released at ...
متن کاملShort-channel functional near-infrared spectroscopy regressions improve when source-detector separation is reduced.
In functional near-infrared spectroscopy (fNIRS) of human cerebral hemodynamics, dedicated surface-sensitive recording channels are useful for regressing out background hemodynamics and isolating activation-specific responses. A wide variety of source-detector separations have been utilized for this purpose. Here, we report a direct comparison of regression performance between two extremes of t...
متن کاملComparison of principal and independent component analysis in removing extracerebral interference from near-infrared spectroscopy signals.
Near-infrared spectroscopy (NIRS) is a method for noninvasive estimation of cerebral hemodynamic changes. Principal component analysis (PCA) and independent component analysis (ICA) can be used for decomposing a set of signals to underlying components. Our objective is to determine whether PCA or ICA is more efficient in identifying and removing scalp blood flow interference from multichannel N...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 82 6 شماره
صفحات -
تاریخ انتشار 1999