A randomized controlled cross-over trial and cost analysis comparing endoscopic ultrasound fine needle aspiration and fine needle biopsy.

نویسندگان

  • A Aziz Aadam
  • Sachin Wani
  • Ashley Amick
  • Janak N Shah
  • Yasser M Bhat
  • Christopher M Hamerski
  • Jason B Klapman
  • V Raman Muthusamy
  • Rabindra R Watson
  • Alfred W Rademaker
  • Rajesh N Keswani
  • Laurie Keefer
  • Ananya Das
  • Srinadh Komanduri
چکیده

BACKGROUND AND STUDY AIMS Techniques to optimize endoscopic ultrasound-guided tissue acquisition (EUS-TA) in a variety of lesion types have not yet been established. The primary aim of this study was to compare the diagnostic yield (DY) of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) to endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for pancreatic and non-pancreatic masses. PATIENTS AND METHODS Consecutive patients referred for EUS-TA underwent randomization to EUS-FNA or EUS-FNB at four tertiary-care medical centers. A maximum of three passes were allowed for the initial method of EUS-TA and patients were crossed over to the other arm based on on-site specimen adequacy. RESULTS A total of 140 patients were enrolled. The overall DY was significantly higher with specimens obtained by EUS-FNB compared to EUS-FNA (90.0 % vs. 67.1 %, P = 0.002). While there was no difference in the DY between the two groups for pancreatic masses (FNB: 91.7 % vs. FNA: 78.4 %, P = 0.19), the DY of EUS-FNB was higher than the EUS-FNA for non-pancreatic lesions (88.2 % vs. 54.5 %, P = 0.006). Specimen adequacy was higher for EUS-FNB compared to EUS-FNA for all lesions (P = 0.006). There was a significant rescue effect of crossover from failed FNA to FNB in 27 out of 28 cases (96.5 %, P = 0.0003). Decision analysis showed that the strategy of EUS-FNB was cost saving compared to EUS-FNA over a wide range of cost and outcome probabilities. CONCLUSIONS RESULTS of this RCT and decision analysis demonstrate superior DY and specimen adequacy for solid mass lesions sampled by EUS-FNB.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) versus fine needle biopsy (FNB) in the diagnosis of solid lesions: study protocol for a randomized controlled trial

BACKGROUND Linear endoscopic ultrasonography (EUS) allows the visualization, identification, and characterization of the extent of lesions of the gastrointestinal (GI) tract and adjacent structures. EUS-guided fine-needle aspiration (EUS-FNA) facilitates a more accurate diagnosis of mediastinal, intra-abdominal, and pancreatic lesions through the collection of the cytological material under dir...

متن کامل

Endoscopic ultrasound guided fine needle aspiration versus endoscopic ultrasound guided fine needle biopsy in sampling pancreatic masses

BACKGROUND The comparison between endoscopic ultrasound guided fine needle aspiration (EUS-FNA) and endoscopic ultrasound guided fine needle biopsy (EUS-FNB) for the diagnosis of pancreatic masses is still controversial. Many factors can affect the final results. METHODS Databases, such as PubMed, EMBASE, Cochrane Library, and Science Citation Index updated from 2000 to 2016 were searched to ...

متن کامل

A Prospective Randomized Controlled Study Comparing EUS Sonopsy CY(R) and 22-gauge Biopsy Needles for Endoscopic Ultrasound-guided Fine-Needle Aspiration of Solid Pancreatic Mass Lesions.

Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is a standard procedure for precise histological diagnosis of pancreas tumors, but it is sometimes difficult to obtain adequate specimens. EUS Sonopsy CY® is a newly designed needle with original features. This randomized study will compare the tissue collection rate of EUS Sonopsy CY® to that of a conventional needle in EUS-FNA. The...

متن کامل

Optimizing Endoscopic Ultrasound Guided Tissue Sampling of the Pancreas

Endoscopic ultrasound is an important innovation in the field of gastrointestinal endoscopy and allows evaluation of many organs in the vicinity of the gastrointestinal tract. Endoscopic ultrasound-fine needle aspiration has been established to be an important tool in the management of pancreaticobiliary disease and is used for screening, staging, biopsy confirmation, and palliation. The accura...

متن کامل

Randomized Trial Comparing the Flexible 19G and 25G Needles for Endoscopic Ultrasound-Guided Fine Needle Aspiration of Solid Pancreatic Mass Lesions

OBJECTIVES Although a large gauge needle can procure more tissue at endoscopic ultrasound-guided fine needle aspiration (EUS-FNA), its advantage over smaller needles is unclear. This study compared flexible 19G and 25G needles for EUS-FNA of solid pancreatic masses. METHODS This was a randomized trial of patients undergoing EUS-FNA of pancreatic masses using flexible 19G or 25G needle. Main o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy international open

دوره 4 5  شماره 

صفحات  -

تاریخ انتشار 2016