Construction Condition and Damage Monitoring of Post-Tensioned PSC Girders Using Embedded Sensors
نویسندگان
چکیده
The potential for monitoring the construction of post-tensioned concrete beams and detecting damage to the beams under loading conditions was investigated through an experimental program. First, embedded sensors were investigated that could measure pre-stress from the fabrication process to a failure condition. Four types of sensors were installed on a steel frame, and the applicability and the accuracy of these sensors were tested while pre-stress was applied to a tendon in the steel frame. As a result, a tri-sensor loading plate and a Fiber Bragg Grating (FBG) sensor were selected as possible candidates. With those sensors, two pre-stressed concrete flexural beams were fabricated and tested. The pre-stress of the tendons was monitored during the construction and loading processes. Through the test, it was proven that the variation in thepre-stress had been successfully monitored throughout the construction process. The losses of pre-stress that occurred during a jacking and storage process, even those which occurred inside the concrete, were measured successfully. The results of the loading test showed that tendon stress and strain within the pure span significantly increased, while the stress in areas near the anchors was almost constant. These results prove that FBG sensors installed in a middle section can be used to monitor the strain within, and the damage to pre-stressed concrete beams.
منابع مشابه
Comparative Study of PSC Box Girder Multi Cell (3-Cell) Bridge of Different Shapes : A Review Paper
A bridge is a structure providing passage over an obstacle without closing the way beneath. The required passage may be for a road, a railway, pedestrians, a canal or a pipeline. Now a days, bridge deck section of Box shapes are used widely. Most of the bridges constructed are of Box girders. Method of post-tensioning in the construction of bridges is very common today. Most of the bridges are ...
متن کاملDevelopment of Embedded EM Sensors for Estimating Tensile Forces of PSC Girder Bridges
The tensile force of pre-stressed concrete (PSC) girders is the most important factor for managing the stability of PSC bridges. The tensile force is induced using pre-stressing (PS) tendons of a PSC girder. Because the PS tendons are located inside of the PSC girder, the tensile force cannot be measured after construction using conventional NDT (non-destructive testing) methods. To monitor the...
متن کاملDamage Detection in Post-tensioned Slab Using 2D Wavelet Transforms
Earthquake force, loading more than structural capacity, cracking, material fatigue and the other unpredicted events were undeniable in the structure life cycle in order that environmental conditions of the structure would be changed and treats health. Damage of structures such as crack, corrosion of the post tension cables from inappropriate grouting of the post tension structures and etc. can...
متن کاملA Pitch-Catch Based Online Structural Health Monitoring of Pressure Vessels, Considering Corrosion Formation
Structural health monitoring is a developing research field which is multifunctional and can estimate the health condition of the structure by data analyzing and also can prognosticate the structural damages. Illuminating the damages by using piezoelectric sensors is one of the most effective techniques in structural health monitoring. Pressurized equipments are very important components in pro...
متن کاملServiceability Response of Rehabilitated Unbonded Post-tensioned Indeterminate I-Beams Consisting UHSSCC
The ultra-high strength self-compacting concrete, UHSSCC is the new generation type of concrete with a compressive strength higher than 80MPa. The application of this type of concrete on the serviceability state in CFRP strengthened unbonded post-tensioned indeterminate I-beam is monitored and the results are compared theoretically using different standards. For this aim, full scale I-beam of 9...