An interlaboratory study of blood-gas analysis: dependence of pO2 and pCO2 results on atmospheric pressure.

نویسندگان

  • R W Burnett
  • M Itano
چکیده

Blood-gas data from a large interlaboratory survey were analyzed to determine whether pO2 and pCO2 results are affected by the atmospheric pressure at the measuring location. A small but statistically significant dependence was found, averaging about 2.3% per 100 mmHg (1.7% per 10 kPa) for pO2 and 1.0% per 100 mmHg (0.75% per 10 kPa) for pCO2.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه گازهای خون بندناف واپگار نوزادان حاصل از زایمان طبیعی و سزارین به روش بیهوشی عمومی وبی حسی نخاعی

Background: Umbilical cord blood gas analysis is a useful method for assessment of oxygenation and acid-base status in neonates. Severe fetal acidemia is associated with increased perinatal mortality and increased risk of subsequent impaired neurological development. Due to high percentage of C/S in our country and the effect of anesthetic medications on umbilical blood gases which can cause ne...

متن کامل

Effects of Rosemary (Rosmarinus officinalis) Extract on Performance, Antioxidant Ability and Blood Gas Indices of Broiler Chickens Treated with Sodium Nitrate in Drinking Water

A total of 220 broiler chicks in five groups were used to reveal the effects of different levels of 0.0, 1.5, 3.0 and 6.0 mL/L rosemary extract along with sodium nitrate (27.4 mg/L) in drinking water as compared to the control (without any supplement in water) on performance and antioxidant potential of treated broiler chickens. Body weight gain and feed conversion ratio were negatively affecte...

متن کامل

Comparison of 4 point-of-care blood gas analyzers for arterial blood gas analysis in healthy dogs and dogs with cardiopulmonary disease.

Objective – To compare blood gas results obtained from4point-of-care (POC) blood gas analyzers under routine working conditions in order to determine their interchangeability. Design – Prospective study. Setting – University teaching hospital. Animals – Arterial blood samples from 34 dogs, 22 presented for cardiorespiratory disease and 12 healthy experimental Beagles. Measurements – Each sample...

متن کامل

Correlation of Arterial Blood Gas Measurements with Venous Blood Gas Values in Mechanically Ventilated Patients

BACKGROUND Arterial blood gas (ABG) analysis is useful in evaluation of the clinical condition of critically ill patients; however, arterial puncture or insertion of an arterial catheter may cause many complications. The aim of this study was to determine whether venous blood gas (VBG) values can be used as an alternative to arterial blood gas measurements in patients under mechanical ventilati...

متن کامل

Inter-instrument comparison of blood gas analyzers and assessment of tonometry using fresh heparinized whole human blood.

Because of limitations associated with commercial blood gas quality controls and tonometry of stored blood, fresh heparinized blood was used to compare PO2 and PCO2 performance of ten blood gas analyzers. Function of nine gas mixer/tonometer systems was evaluated. These were used to create blood samples with target values for PO2 and PCO2. All ten analyzers had high precision; this magnified sm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 8  شماره 

صفحات  -

تاریخ انتشار 1989