Forces and moments on posterior teeth generated by incisor intrusion biomechanics.
نویسندگان
چکیده
OBJECTIVES To comparatively evaluate the extrusive forces and torquing moments on the posterior dentition generated during anterior intrusion with different intrusion techniques in the maxillary and mandibular dental arch. MATERIAL AND METHODS Seven wire specimens were used for each of the following intrusive arches: Utility arch 0.016 x 0.016' Blue Elgiloy, Utility arch 0.017 x 0.025' TMA and Burstone Intrusion arch 0.017 x 0.025' TMA. The wires were inserted on bracketed dental arches constructed on maxillary Frasaco models, segmented mesially to the maxillary canines. Simulated intrusion from 0.0-3.0 mm was performed on the Orthodontic Measurement and Simulation System (OMSS). The forces and moments were recorded in all three planes of space at 0.1 mm increments and the values at 3.0 mm for all wires were used for all statistical evaluations. The data were analyzed, separately for the forces and moments, by means of two-way analysis of variance (ANOVA) with forces and moments serving as the dependent variables and intrusion technique and jaw (maxilla or mandible) as the independent variable. Post hoc multiple comparisons were performed using the Tukey test at .05 error rate. RESULTS The 0.016 x 0.016' Blue Elgiloy utility arch exerted the highest posterior extrusive forces, 15% higher than the 0.017 x 0.025' TMA utility and 40% higher in comparison with the 0.017 x 0.025' TMA Burstone intrusion arch.The lowest posterior moment in the sagittal plane was generated by the 0.017 x 0.025' TMA Burstone intrusion arch. The 0.016 x 0.016' Blue Elgiloy utility arch exerted 15% higher posterior moments and the 0.017 x 0.025' TMA utility 25% higher. Forces and moments were consistently larger for the mandible compared to the maxilla for the same intrusion technique. CONCLUSIONS The upper Burstone 0.017 x 0.025' TMA intrusion arch exerted the lowest forces/moments on posterior teeth. The highest forces were generated by the 0.016 x 0.016-inch Blue Elgiloy utility arch and the highest moments by the lower 0.017 x 0.025-inch TMA utility arch.
منابع مشابه
A comparative assessment of the forces and moments generated with various maxillary incisor intrusion biomechanics.
The aim of this study was to comparatively evaluate the intrusive forces and buccolingual torquing moments generated during anterior maxillary intrusion using different maxillary incisor intrusion mechanics. Five wire specimens were used for each of the following intrusive arches: blue Elgiloy utility arch 0.016 x 0.016 inch, TMA utility arch 0.017 x 0.025 inch, Burstone TMA intrusion arch 0.01...
متن کاملQuantification of intrusive/retraction force and moment generated during en-masse retraction of maxillary anterior teeth using mini-implants: A conceptual approach
OBJECTIVE The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction using mini-implants. METHODS The optimum force required for en-masse intrusion and retraction c...
متن کاملAn investigation on stress distribution of the anterior maxillary teeth PDL during the application of intrusive forces in midline
An investigation on stress distribution of the anterior maxillary teeth PDL during the application of intrusive forces in midline Dr. S.M. Abtahi * - Dr. F. Heravi** * - Assistant professor of Orthodontics Dept. Faculty of Dentistry Hamedan University of Medical Sciences. ** - Assistant professor of Orthodontics Dept. Faculty of Dentistry Mashhad University of Medical Sciences. Background an...
متن کاملHigh Force Levels Can Be Delivered With Thermoplastic Aligners Initial Forces Generated by Three Types of Thermoplastic Appliances on an Upper Central Incisor During Tipping
Background: Treatment of minor malocclusions with clear thermoplastic aligners is more commonly being used as an aesthetic alternative to fixed appliances. This can be done by manually resetting teeth on a plaster model or by models generated from a 3D computer model (Invisalign®). However, little research has been performed on the complex force systems generated by these types of appliances. O...
متن کاملThree-dimensional orthodontic force measurements.
INTRODUCTION Until recently, much of the orthodontic biomechanics literature was restricted to 2-dimensional experimental studies and, more recently, to assumption-based 3-dimensional computer modeling. There is little evidence in the literature regarding 3-dimensional experimental measurements and analysis of orthodontic force systems. METHODS The purpose of this study was the design, constr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthodontics & craniofacial research
دوره 12 4 شماره
صفحات -
تاریخ انتشار 2009