Hollow Fiber Membrane Dehumidification Device for Air Conditioning System

نویسندگان

  • Baiwang Zhao
  • Na Peng
  • Canzeng Liang
  • Wai Fen Yong
  • Tai-Shung Chung
  • Alexey Volkov
چکیده

In order to provide a comfortable living and working environment indoors in tropical countries, the outdoor air often needs to be cooled and dehumidified before it enters the rooms. Membrane separation is an emerging technology for air dehumidification and it is based on the solution diffusion mechanism. Water molecules are preferentially permeating through the membranes due to its smaller kinetic diameter and higher condensability than the other gases. Compared to other dehumidification technologies such as direct cooling or desiccation, there is no phase transition involved in membrane dehumidification, neither the contact between the fresh air stream and the desiccants. Hence, membrane dehumidification would not only require less energy consumption but also avoid cross-contamination problems. A pilot scale air dehumidification system is built in this study which comprises nine pieces of one-inch PAN/PDMS hollow fiber membrane modules. A 150 h long-term test shows that the membrane modules has good water vapor transport properties by using a low vacuum force of only 0.78 bar absolute pressure at the lumen side. The water vapor concentration of the feed humid air decreases dramatically from a range of 18-22 g/m³ to a range of 13.5-18.3 g/m³. Most importantly, the total energy saving is up to 26.2% compared with the conventional air conditioning process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlated Effect of Air Gap and PVP Concentration on the Structure and Performance of PVDF Ultrafiltration Hollow Fiber Membrane

Polyvinylidene fluoride/polyvinylpyrrolidone (PVDF/PVP) hollow fiber membranes were fabricated by dry-jet wet-spinning process. The correlated effects of the air gap length and PVP concentration ((1) the air gap length effect at the low and high PVP concentration in the dope solutions, as well as (2) the effect of the PVP concentration at the same air gap length) on the cross-section structure ...

متن کامل

Application of Salt Additives and Response Surface Methodology for Optimization of PVDF Hollow Fiber Membrane in DCMD and AGMD Processes

In this study, the influence of the salts as an additive on the performance of the membrane was investigated and an extensive work was performed to optimize PVDF hollow fiber membranes through a response surface methodology (RSM). The prepared membranes were characterized by SEM, contact angle and LEP measurement. Then, the RSM was used for the optimization of surface pore size, porosity and hy...

متن کامل

Influence of Air-Gap Length on CO2 Stripping from Diethanolamine Solution and Water Performance of Surface Modified PVDF Hollow Fiber Membrane Contactor

Surface Modifying Macromolecule (SMM) blended PVDF hollow fibers (HFs) were spun at different air-gaps (o to 20 cm) and used for CO2 stripping from aqueous DEA solution and water. The manufactured fibers were first subjected to various characterization tests such as contact angle and critical water entry pressure measurement to evaluate the HF hydrophobicity and wetting resistanc...

متن کامل

Theoretical and Experimental Analysis of Desiccant Air Conditioning System for Storage of Agricultural Products

The study emphasizes on the use of desiccant air conditioning (DAC) system for the storage of agricultural products. The chilling sensitivity of the tropical fruits and vegetables makes this system more promising for their optimal storage. The desiccant air conditioning system assisted by Maisotsenko cycle evaporative cooler is proposed in the study to achieve the latent and sensible load of ai...

متن کامل

Exergy Analysis of an Air Dehumidification System Equipped with Mixing Box and Heat Exchanger Heat Recovery Units

Exergy analysis emboldens in cases that all the inefficiencies and bottlenecks to improve energy systems are to be addressed. In this study, a novel vapor compression air dehumidifier integrated with an auxiliary heat exchanger in series arrangement with the main condenser in order to mitigate the reheat coil, and an extra mixing box to recover the ventilated air heat has been introduced. A com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015