Purpose To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods This was an institutional review board-approved and HIPAA-compliant retrospective interpretation of prospectively acquired data with waiver of informed consent. Compared were recall rates, biopsy rates, cancer detection rates, and radiation dose for 15 571 women screened with digital mammography/DBT from October 1, 2011, to February 28, 2013, and 5366 women screened with s2D/DBT from January 7, 2015, to June 30, 2015. Two-sample z tests of equal proportions were used to determine statistical significance. Results Recall rate for s2D/DBT versus digital mammography/DBT was 7.1% versus 8.8%, respectively (P < .001). Biopsy rate for s2D/DBT versus digital mammography/DBT decreased (1.3% vs 2.0%, respectively; P = .001). There was no significant difference in cancer detection rate for s2D/DBT versus digital mammography/DBT (5.03 of 1000 vs 5.45 of 1000, respectively; P = .72). The average glandular dose was 39% lower in s2D/DBT versus digital mammography/DBT (4.88 mGy vs 7.97 mGy, respectively; P < .001). Conclusion Screening with s2D/DBT in a large urban practice resulted in similar outcomes compared with digital mammography/DBT imaging. Screening with s2D/DBT allowed for the benefits of DBT with a decrease in radiation dose compared with digital mammography/DBT. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on August 11, 2016.
منابع مشابه
Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملClinical Performance of Synthesized Two-dimensional Mammography Combined with Tomosynthesis in a Large Screening Population.
Purpose To compare the clinical performance of synthesized two-dimensional (s2D) mammography combined with digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) alone and FFDM combined with DBT in a large community-based screening population by analyzing recall rate, positive predictive value, and cancer detection rate. Materials and Methods This was a retrospect...
متن کاملDigital Breast Tomosynthesis (DBT)
DBT is a three-dimensional (3D) breast imaging technology that uses a rotating X-ray source to acquire multiple image slices at several angles. The X-ray source rotates around the breast in an arc. Serial exposures are taken every few degrees in the arc rotation. These images are then reconstituted by software to produce a 3Dimage of the breast, similar to CAT scanning. It has been suggested th...
متن کاملDigital Breast Tomosynthesis - 06/13
Digital breast tomosynthesis (DBT) is being developed as an approach to generate images that may improve the sensitivity and specificity of mammography. Current radiographic approaches to mammography produce two-dimensional (2D) images. These 2D systems can have limitations due to overlapping tissue in the breast that may hide lesions (cancers) or cause benign masses to appear suspicious. DBT, ...
متن کاملMM.05.012 Digital Breast Tomosynthesis - 8/14
Digital breast tomosynthesis (DBT) is being developed as an approach to generate images that may improve the sensitivity and specificity of mammography. Current radiographic approaches to mammography produce two-dimensional (2D) images. These 2D systems can have limitations due to overlapping tissue in the breast that may hide lesions (cancers) or cause benign masses to appear suspicious. DBT, ...