Radial dilation force of tipless and helical stone baskets.

نویسندگان

  • Kari Hendlin
  • Courtney Lee
  • J Kyle Anderson
  • Manoj Monga
چکیده

PURPOSE To evaluate one aspect of tipless and helical stone basket function that is critical for ureteral stone extraction: the radial-dilation force. MATERIALS AND METHODS Nine commercially available tipless baskets and five commercially available helical stone baskets were tested. Two Teflon blocks were positioned with the lower block sitting on a digital scale and the upper block secured to a plastic frame and base. A 0.01-inch gap was maintained between the blocks using a digital micrometer. Alignment pins secured the position of the lower block in relation to the upper block. A 4-mm cylindrical hole was drilled through the center of the block interface, and each basket was passed through the hole and opened to its fully extended length. The basket was then slowly retracted through the hole, and the maximum force reading was recorded. Twenty repetitions were performed for each basket. RESULTS Of the tipless baskets > or =3.0F, the Cook N-Circle 3.2F provided the best radial dilation (24.7 +/- 0.4 g). For tipless baskets <3.0F, the Sacred Heart Vantage 2.4F provided the best radial dilation (19.6 +/- 0.8 g). Of the helical baskets, the Sacred Heart Hercules provided the most radial dilation (102 +/- 12.1 g) followed by the Cook N-Force (71.8 +/- 4.3 g). CONCLUSION The radial-dilation force of tipless and helical stone baskets differs significantly among baskets and may impact stone extraction performance in the ureter.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Basket design as a factor in retention and release of calculi in vitro.

PURPOSE To compare stone retrieval and release from seven basket designs in vitro. MATERIALS AND METHODS We tested two tipped and one tipless NCompass models, three other tipless Nitinol designs (NCircle, Sur-Catch, and Dimension), and the Segura Hemisphere for their ability to retrieve and release single beads 8, 6, 5.6, and 5 mm diameter and multiple beads 3.6 mm diameter in both a ureteral...

متن کامل

Systematic evaluation of ureteral occlusion devices: insertion, deployment, stone migration, and extraction.

OBJECTIVES To compare 4 ureteral occlusion devices in terms of insertion force, maneuverability, radial dilation and extraction forces, ability to prevent stone migration, and tip stiffness. METHODS The devices tested were the PercSys Accordion, Microvasive Stone Cone (7 and 10 mm), and Cook N-Trap. Using a ureteral model with an artificial stone in place, the insertion force, number of attem...

متن کامل

Endourology and Stone Diseases Retrograde Flexible Ureteroscopic Approach for Pyelocaliceal Calculi

Introduction: Our goal was to investigate the efficacy of flexible ureteroscopy (FU) in the treatment of pyelocaliceal calculi. Materials and Methods: Between September 2002 and December 2004, a total of 41 patients with multiple (23 cases), pelvic (7 cases), and inferior caliceal (11 cases) SWL-resistant calculi underwent FU. We used a 7.5-F flexible ureteroscope with pressure irrigation and e...

متن کامل

Effects of Helix Angle Variations on Stability of Low Immersion Milling

The stability behavior of low immersion helical end milling processes is investigated in this paper. Low radial immersion milling operations involve interrupted cutting which induces chatter vibration under certain cutting conditions. Time Finite Element Analysis (TFEA) is suggested for an approximate solution for delayed differential equations encountered during interrupted milling. An improve...

متن کامل

In vitro head-to-head comparison of the durability, versatility and efficacy of the NGage and novel Dakota stone retrieval baskets

Background To compare head to head two end-engaging nitinol stone retrieval devices available to urologists, in terms of durability, versatility and efficacy. Methods For durability testing, 30 NGage and Dakota baskets were cycled 20 times between grasping and releasing synthetic stone models and evaluated for damage or device failure. For versatility and efficacy testing, baskets were assess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of endourology

دوره 18 10  شماره 

صفحات  -

تاریخ انتشار 2004