Study of intestinal flow by combined videofluoroscopy, manometry, and multiple intraluminal impedance.

نویسندگان

  • Hala Imam
  • Claudia Sanmiguel
  • Brett Larive
  • Yasser Bhat
  • Edy Soffer
چکیده

Assessment of patterns of flow in the small bowel is difficult. Multiple intraluminal impedance has been recently used for study of flow dynamics in the esophagus. Our aims were 1) to validate multiple intraluminal impedance by correlating impedance events with intestinal flow as detected by fluoroscopy and 2) to determine intestinal flow patterns in the fasting and postprandial period and their correspondence with manometry. First, six healthy subjects underwent simultaneous video-fluoroscopic, manometric, and impedance recording from the duodenum. Videofluoroscopy was used to validate impedance patterns corresponding with barium flow in the fasting and postprandial periods. Next, 16 healthy subjects underwent prolonged simultaneous recording of impedance and manometry in both periods. Most flow events were short (10 cm or less), with antegrade flow being the most common. Correspondence between impedance and videofluoroscopy increased with increasing length of barium flow. Impedance corresponded better with flow, at any distance, than manometry. However, impedance and manometric events, when analyzed separately as index events, always corresponded with fluoroscopic flow. The fasting and postprandial periods showed comparable patterns of flow, with frequent, highly propulsive manometric and impedance sequences. Motility index was positively and significantly associated with length of impedance events. Phase 3 of the migrating motor complex could be easily recognized by impedance. Multiple intraluminal impedance can detect intestinal flow events and corresponds better with fluoroscopic flow than manometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Upper esophageal sphincter impedance as a marker of sphincter opening diameter.

The measurement of the physical extent of opening of the upper esophageal sphincter (UES) during bolus swallowing has to date relied on videofluoroscopy. Theoretically luminal impedance measured during bolus flow should be influenced by luminal diameter. In this study, we measured the UES nadir impedance (lowest value of impedance) during bolus swallowing and assessed it as a potential correlat...

متن کامل

Assessment of intraluminal impedance for the detection of pharyngeal bolus flow during swallowing in healthy adults.

Intraluminal impedance, a nonradiological method for assessing bolus flow within the gut, may be suitable for investigating pharyngeal disorders. This study evaluated an impedance technique for the detection of pharyngeal bolus flow during swallowing. Patterns of pharyngoesophageal pressure and impedance were simultaneously recorded with videofluoroscopy in 10 healthy volunteers during swallowi...

متن کامل

Clinical Applications of Esophageal Multichannel Intraluminal Impedance Testing.

Multichannel intraluminal impedance is a relatively new technology that allows detection of bolus movement in the gastrointestinal tract without the use of radiation. In clinical applications it is combined with manometry, allowing a better evaluation of the functional characteristics (ie, bolus transit) of esophageal motility abnormalities. When combined with pH monitoring, it provides more co...

متن کامل

Characterization of Esophageal Physiology Using Mechanical State Analysis

The esophagus functions to transport swallowed fluids and food from the pharynx to the stomach. The esophageal muscles governing bolus transport comprise circular striated muscle of the proximal esophagus and circular smooth muscle of the distal esophagus. Longitudinal smooth muscle contraction provides a mechanical advantage to bolus transit during circular smooth muscle contraction. Esophagea...

متن کامل

Flow time through esophagogastric junction derived during high-resolution impedance-manometry studies: a novel parameter for assessing esophageal bolus transit.

This study aimed to develop and validate a method to measure bolus flow time (BFT) through the esophagogastric junction (EGJ) using a high-resolution impedance-manometry (HRIM) sleeve. Ten healthy subjects were studied with concurrent HRIM and videofluoroscopy; another 15 controls were studied with HRIM alone. HRIM studies were performed using a 4.2-mm-outer diameter assembly with 36 pressure s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Gastrointestinal and liver physiology

دوره 286 2  شماره 

صفحات  -

تاریخ انتشار 2004