‘Optimized’ LV only pacing using a dual chamber pacemaker as a cost effective alternative to CRT

نویسندگان

  • Maneesh K. Rai
  • Mukund A. Prabhu
  • Abhishek Sharma
  • Ritesh Vekariya
  • Padmanabh Kamath
  • Narasimha Pai
  • Ramanath L. Kamath
چکیده

BACKGROUND Cardiac Resynchronization therapy (CRT) remains largely under-used in developing countries owing to the high cost of therapy. In this pilot study, we explore 'optimized' Left Ventricle Only Pacing (LVOP) as a cost effective alternative to cardiac resynchronization therapy in selected patients with heart failure. HYPOTHESIS In economically poorer patients with heart failure, left bundle branch block (LBBB) and intact AV node conduction, synchronization can be obtained using a dual chamber pacemaker (leads in right atrium and Left ventricle) with the help of 2D strain imaging. METHODS AND RESULTS 4 patients underwent LVOP for symptomatic heart failure. Post procedure 'optimization' was done using 12 lead electrocardiography and 2D- Strain imaging. Difference between Time to Peak longitudinal strain and Aortic valve Closure (Diff TPL-AC) was calculated for each segment at different AV delays and the AV delay with the smallest Diff TPL-AC was programmed. The mean AV delay that resulted in electrical and mechanical synchrony was 150 ms. After a mean follow up of 6 months, all patients had improved by at least 1 NYHA class. The mean reduction in QRS duration post procedure was -54.5 ± 22.82 ms and the mean improvement in EF was 7 ± 2.75%. CONCLUSION Optimized LVOP using 2D strain and ECG can be a cost-effective alternative to CRT in patients with LBBB, heart failure and normal AV node conduction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal pacing for right ventricular and biventricular devices: minimizing, maximizing, and right ventricular/left ventricular site considerations.

The results from numerous clinical studies provide guidance for optimizing outcomes related to RV or biventricular pacing in the pacemaker and ICD populations. (1) Programming algorithms to minimize RV pacing is imperative in patients with dual-chamber pacemakers who have intrinsic AV conduction or intermittent AV conduction block. (2) Dual-chamber ICDs should be avoided in candidates without a...

متن کامل

Left Ventricular Pacing In Patients With Congestive Heart Failure

Cardiac resynchronisation therapy (CRT) using biventricular (BIV) pacing has proved its effectiveness to correct myocardial asynchrony and improve clinical status of patients with severe congestive heart failure (CHF) and widened QRS. Despite a different effect on left ventricular electrical dispersion, left univentricular (LV) pacing is able to achieve the same mechanical synchronisation as BI...

متن کامل

When limited by cost in CRT-be a leftist!

Cardiac resynchronization therapy (CRT) over last two decades has transformed the management expectations of diligently selected patients with systolic heart failure. While the true inception of the idea dates back to 1925 when Wiggers showed that surface stimulation of the caninemyocardium reduced themaximal LV pressure derivative (LV dP/dtmax) and lengthened isometric contraction, the observa...

متن کامل

Intermittent loss of capture in a His bundle pacemaker: What is the cause?

Case report A 34-year-old man with a history of congenital complete heart block who underwent dual-chamber pacemaker implant at age 6 and multiple generator changes was referred for device replacement and lead extraction owing to malfunctioning atrial and ventricular leads. He underwent lead extraction of a dual-chamber pacing system with subsequent reimplantation of a Medtronic Viva CRT pacema...

متن کامل

Optimizing the Atrioventricular Delay in Dual Chamber Pacemakers; Is It Worth?

Submit Manuscript | http://medcraveonline.com Abbreviations: AV: Atrio-Ventricular; AVD: Atrio-Ventricular Delay; AVI: Atrio-Ventricular Interval; CO: Cardiac Output; CRT: Cardiac Resynchronization Therapy; DDD: Dual Chamber Pacemaker with Dual Pacing-Dual Sensing-Dual Response to Heart Rate; ECG: Electrocardiogram; EF: Ejection Fraction; IQR: Interquartile Range; LA: Left Atrium; LAP: Left Atr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017