The oversampling phasing method.

نویسندگان

  • J Miao
  • J Kirz
  • D Sayre
چکیده

Sampling the diffraction pattern of a finite specimen more finely than the Nyquist frequency (the inverse of the size of the diffracting specimen) corresponds to surrounding the electron density of the specimen with a no-density region. When the no-density region is bigger than the electron-density region, sufficient information is recorded so that the phase information can be retrieved from the oversampled diffraction pattern, at least in principle. By employing an iterative algorithm, the phase information from the oversampled diffraction pattern of a micrometre-sized test specimen has been successfully retrieved. This method is believed to be able to open a door for high-resolution three-dimensional structure determination of complex and non-crystalline biological specimens, i.e. whole cells and sub-micrometre molecular clusters and micrometre-sized protein crystals. With the possible appearance in the future of X-ray free-electron lasers, it may become possible to image single molecules by recording diffraction patterns before radiation damage manifests itself.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase retrieval of diffraction patterns from noncrystalline samples using the oversampling method

We report the experiments and procedures to successfully record and reconstruct coherent diffraction patterns at sub-10-nm resolution from noncrystalline samples by using synchrotron x rays with a wavelength of 2 Å. By employing the oversampling phasing method, we studied the quality of image reconstruction of experimental diffraction patterns as a function of the oversampling ratio ~a paramete...

متن کامل

Phase retrieval with random phase illumination.

This paper presents a detailed numerical study on the performance of the standard phasing algorithms with random phase illumination (RPI). Phasing with high resolution RPI and the oversampling ratio σ=4 determines a unique phasing solution up to a global phase factor. Under this condition, the standard phasing algorithms converge rapidly to the true solution without stagnation. Excellent approx...

متن کامل

High resolution 3D x-ray diffraction microscopy.

We have imaged a 2D buried Ni nanostructure at 8 nm resolution using coherent x-ray diffraction and the oversampling phasing method. By employing a 3D imaging reconstruction algorithm, for the first time we have experimentally determined the 3D structure of a noncrystalline nanostructured material at 50 nm resolution. The 2D and 3D imaging resolution is currently limited by the exposure time an...

متن کامل

Atomic resolution three-dimensional electron diffraction microscopy.

We report the development of a novel form of diffraction-based 3D microscopy to overcome resolution barriers inherent in high-resolution electron microscopy and tomography. By combining coherent electron diffraction with the oversampling phasing method, we show that the 3D structure of a nanocrystal can be determined ab initio at a resolution of 1 A from 29 simulated noisy diffraction patterns....

متن کامل

Phase retrieval from the magnitude of the Fourier transforms of nonperiodic objects

It is suggested that, given the magnitude of Fourier transforms sampled at the Bragg density, the phase problem is underdetermined by a factor of 2 for 1D, 2D, and 3D objects. It is therefore unnecessary to oversample the magnitude of Fourier transforms by 23 in each dimension (i.e., oversampling by 43 for 2D and 83 for 3D) in retrieving the phase of 2D and 3D objects. Our computer phasing expe...

متن کامل

روابط جدید زمان چرخه بهینه برای تقاطع‌های پیش‌زمان‌بندی شده مستقل با تغییر رابطه وبستر براساس روش HCM 2000

When the degree of saturation at intersection approaches one, Webster’s optimum cycle length equation becomes inapplicable, because the cycle length will becomes very big when the degree of saturation approaches one and will be fully unrealistic when the degree of saturation becomes greater than one. This is not a problem for HCM2000 method. But optimum cycle length calculation in this method h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta crystallographica. Section D, Biological crystallography

دوره 56 Pt 10  شماره 

صفحات  -

تاریخ انتشار 2000