Does a simple bedside sonographic measurement of the inferior vena cava correlate to central venous pressure?

نویسندگان

  • Robert A De Lorenzo
  • Michael J Morris
  • Justin B Williams
  • Timothy F Haley
  • Timothy M Straight
  • Victoria L Holbrook-Emmons
  • Juanita S Medina
چکیده

BACKGROUND Bedside ultrasound has been suggested as a non-invasive modality to estimate central venous pressure (CVP). OBJECTIVE Evaluate a simple bedside ultrasound technique to measure the diameter of the inferior vena cava (IVC) and correlate to simultaneously measured CVP. Secondary comparisons include anatomic location, probe orientation, and phase of respiration. METHODS An unblinded prospective observation study was performed in an emergency department and critical care unit. Subjects were a convenience sample of adult patients with a central line at the superior venocaval-atrial junction. Ultrasound measured transverse and longitudinal diameters of the IVC at the subxiphoid, suprailiac, and mid-abdomen, each measured at end-inspiration and end-expiration. Correlation and regression analysis were used to relate CVP and IVC diameters. RESULTS There were 72 subjects with a mean age of 67 years (range 21-94 years), 37 (53%) male, enrolled over 9 months. Seven subjects were excluded for tricuspid valvulopathy. Primary diagnoses were: respiratory failure 12 (18%), sepsis 11 (17%), and pancreatitis 3 (5%). There were 28 (43%) patients mechanically ventilated. Adequate measurements were obtainable in 57 (89%) using the subxiphoid, in 44 (68%) using the mid-abdomen, and in 28 (43%) using the suprailiac views. The correlation coefficients were statistically significant at 0.49 (95% confidence interval [CI] 0.26-0.66), 0.51 (95% CI 0.23-0.71), and 0.50 (95% CI 0.14-0.74) for end-inspiratory longitudinal subxiphoid, midpoint, and suprailiac views, respectively. Transverse values were statistically significant at 0.42 (95% CI 0.18-0.61), 0.38 (95% CI 0.09-0.61), and 0.67 (95% CI 0.40-0.84), respectively. End-expiratory measurements gave similar or slightly less significant values. CONCLUSION The subxiphoid was the most reliably viewed of the three anatomic locations; however, the suprailiac view produced superior correlations to the CVP. Longitudinal views generally outperformed transverse views. A simple ultrasound measure of the IVC yields weak correlation to the CVP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...

متن کامل

The efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation

Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...

متن کامل

The efficacy of sonographic measurement of inferior vena cava diameter as an estimate of central venous pressure

BACKGROUND Central venous pressure (CVP) and right atrial pressure (RAP) are important parameters in the complete hemodynamic assessment of a patient. Sonographic measurement of the inferior vena cava (IVC) diameter is a non-invasive method of estimating these parameters, but there are limited data summarizing its diagnostic accuracy across multiple studies. We performed a comprehensive review ...

متن کامل

Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure.

STUDY OBJECTIVE Among adult emergency department (ED) patients undergoing central venous catheterization, we determine whether a greater than or equal to 50% decrease in inferior vena cava diameter is associated with a central venous pressure of less than 8 mm Hg. METHODS Adult patients undergoing central venous catheterization were enrolled in a prospective, observational study. Inferior ven...

متن کامل

Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

INTRODUCTION The correlation of central venous pressure (CVP) with inferior vena cava (IVC) sonographic diameter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of emergency medicine

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 2012