Fatigue strength of bovine articular cartilage-on-bone under three-point bending: the effect of loading frequency
نویسندگان
چکیده
BACKGROUND The objective of this study was to determine the influence of loading frequency on the failure of articular cartilage-on-bone specimens under three-point bending. METHODS In this study, cyclic three-point bending was used to introduce failure into cartilage-on-bone specimens at varying loading frequencies. Sinusiodally varying maximum compressive loads in the range 40-130 N were applied to beam-shaped cartilage-on-bone specimens at frequencies of 1, 10, 50 and 100 Hz. RESULTS The number of cycles to failure decreased when loading frequency increased from normal and above gait (1 and 10 Hz) to impulsive loading frequencies (50 and 100 Hz). It was found that 67 and 27% of the specimens reached run-out at loading of 10,000 cycles at frequencies of 1 and 10 Hz, respectively. However, 0% of the specimens reached run-out at loading frequencies of 50 and 100 Hz. CONCLUSION The results indicate that increasing the loading frequency reduces the ability of specimens to resist fracture during bending. The findings underline the importance of the loading frequency concerning the failure of articular cartilage-on-bone and it may have implications in the early onset of osteoarthritis.
منابع مشابه
Mesenchymal stem cells can survive on the extracellular matrix-derived decellularized bovine articular cartilage scaffold
Objective (s): The scarcity of articular cartilage defect to repair due to absence of blood vessels and tissue engineering is one of the promising approaches for cartilage regeneration. The objective of this study was to prepare an extracellular matrix derived decellularized bovine articular cartilage scaffold and investigate its interactions with seeded rat bone marrow mesenchymal stem cells (...
متن کاملAssessment of different methods for fatigue life prediction of steel in rotating bending and axial loading
Generally, fatigue failure in an element happens at the notch on a surface where the stress level rises because of the stress concentration effect. The present paper investigates the effect of a notch on the fatigue life of the HSLA100 (high strength low alloy) steel which is widely applicable in the marine industry. Tensile test was conducted on specimens and mechanical properties were obtain...
متن کاملViscoelastic properties of bovine articular cartilage attached to subchondral bone at high frequencies
BACKGROUND Articular cartilage is a viscoelastic material, but its exact behaviour under the full range of physiological loading frequencies is unknown. The objective of this study was to measure the viscoelastic properties of bovine articular cartilage at loading frequencies of up to 92 Hz. METHODS Intact tibial plateau cartilage, attached to subchondral bone, was investigated by dynamic mec...
متن کاملThe Effect of Mesenchymal Stem Cells and Aqueous Extract of Elaeagnus Angustifolia on the Mechanical Properties of Articular Cartilage in an Experimental Model of Rat Osteoarthritis
Introduction: Although, the effect of direct intra-articular injection of bone marrow stem cells (BMSCs) on the repair of articular cartilage and the effect of Elaeagnus angustifolia extract on pain relief in patients with osteoarthritis have been investigated, no studies has been conducted to compare the effects of these two therapeutic methods on the mechanical properties of articular cartila...
متن کاملMulti-scalar mechanical testing of the calcified cartilage and subchondral bone comparing healthy vs early degenerative states.
OBJECTIVE The calcified cartilage layer is thought to be integral to force transmission between the compliant articular cartilage (AC) above and underlying stiff bone. This study aims to determine how such a stiffness gradient across the calcified cartilage and bone changes with joint degeneration and how different scalar levels of testing are correlated. METHOD Using a bovine model of early ...
متن کامل