A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy

نویسندگان

  • Peng-Yi Lee
  • Chih-Yuan Lin
  • Shang-Wen Chen
  • Chun-Ru Chien
  • Chun-Nan Chu
  • Hsiu-Ting Hsu
  • Ji-An Liang
  • Ying-Jun Lin
  • An-Cheng Shiau
چکیده

BACKGROUND To improve local control rate in patients with breast cancer receiving adjuvant radiotherapy after breast conservative surgery, additional boost dose to the tumor bed could be delivered simultaneously via the simultaneous integrated boost (SIB) modulated technique. However, the position of tumor bed kept changing during the treatment course as the treatment position was aligned to bony anatomy. This study aimed to analyze the positional uncertainties between bony anatomy and tumor bed, and a topology-based approach was derived to stratify patients with high variation in tumor bed localization. METHODS Sixty patients with early-stage breast cancer or ductal carcinoma in situ were enrolled. All received adjuvant whole breast radiotherapy with or without local boost via SIB technique. The delineation of tumor bed was defined by incorporating the anatomy of seroma, adjacent surgical clips, and any architectural distortion on computed tomography simulation. A total of 1740 on-board images were retrospectively analyzed. Positional uncertainty of tumor bed was assessed by four components: namely systematic error (SE), and random error (RE), through anterior-posterior (AP), cranial-caudal (CC), left-right (LR) directions and couch rotation (CR). Age, tumor location, and body-mass factors including volume of breast, volume of tumor bed, breast thickness, and body mass index (BMI) were analyzed for their predictive role. The appropriate margin to accommodate the positional uncertainty of the boost volume was assessed, and the new plans with this margin for the tumor bed was designed as the high risk planning target volume (PTV-H) were created retrospectively to evaluate the impact on organs at risk. RESULTS In univariate analysis, a larger breast thickness, larger breast volume, higher BMI, and different tumor locations correlated with a greater positional uncertainty of tumor bed. However, BMI was the only factor associated with displacements of surgical clips in the multivariate analysis and patients with higher BMI were stratified as high variation group. When image guidance was aligned to bony structures, the SE and RE of clip displacement were consistently larger in the high variation group. The corresponding PTV-H margins for the high- and low-variation groups were 7, 10, 10 mm and 4, 9, 6 mm in AP, CC, LR directions, respectively. The heart dose between the two plans was not significantly different, whereas the dosimetric parameters for the ipsilateral lung were generally higher in the new plans. CONCLUSIONS In patients with breast cancer receiving adjuvant radiotherapy, a higher BMI is associated with a greater positional uncertainty of the boost tumor volume. More generous margin should be considered and it can be safely applied through proper design of beam arrangement with advanced treatment techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam

Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradia­tion in post‑lump...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Evaluating the effects of esophageal and breast cancer radiotherapy on the cardiac function and determining the relationship between the dosimetric parameters and ejection fraction changes

Background: In the radiotherapy of patients with esophagus and breast cancer, the heart receives a significant dose of radiation that might cause heart complications. Thefore, the aim of the current study was to evaluate the effects of esophagus and left breast cancer radiotherapy on the cardiac function and to determine the relationship between the dosimetric parameters and ejection fraction (...

متن کامل

Comparison of two radiation techniques in breast boost delivery

Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017