Constant-area applanation tonography.

نویسندگان

  • R A Moses
  • W J Grodzki
  • R J Arnzen
چکیده

A tonography device, based on the MacKay-Marg tonometer, has been constructed which will applanate the cornea to a preselected area of 5.0 to 6.0 mm diameter and maintain that applanation area. The pressure decrease with time should resemble the pressure decrease following bolus injection of fluid into the eye. In most cases the pressure decreased in a linear slope, abruptly terminating in a pressure plateau. In most cases, the pressure after 4 min of tonography was lower than preliminary Goldmann applanation pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of miotics on the intraocular pressure of conscious owl monkeys

1. Nissen, O. I., and Hoppe, R.: The facility of aqueous outflow calculated from the rate of fall in applanation pressure after intravenous acetazolamide in man, Acta Ophthalmol. 52: 390, 1974. 2. Nissen, O. I.: The immediate response in applanation pressure to intravenous acetazolamide in primary glaucomas and glaucoma suspects, Acta Ophthalmol. 53: 537, 1975. 3. Grant, W. M.: Tonographic meth...

متن کامل

Provocative test combining water drinking and homatropine eye drops. Applanation versus tonography.

In a previous study (Leighton, Phillips, and Gibbs, 1970), a provocative outflow test using a combination of water drinking (20 ml./kg. body weight) and gutt. homatropine 2 per cent. in 24 open-angle glaucoma suspects caused a significantly greater fall in outflow facility and rise in outflow resistance than either water drinking alone or homatropine alone (0o02 < P < o0os in each case). When a...

متن کامل

Experimental tonography on enucleated human eyes. I. The validity of Grant's tonography formula.

When newer tables for parameters in Grant's formula for tonography are used, one obtains far higher values for the outflow facility than those generally accepted. The aim of this iinvestigation has, therefore, been to test the validity of the tonography formula. The outflow facility determined by constant-rate perfusion in enucleated eyes has been compared with the results of tonography on the ...

متن کامل

The influence of position on intraocular pressure.

To better understand the relationship of Schi0tz pressure determination (in the recumbent position) to Goldmann applanation pressure determinations (in the sitting position), we studied, the change in intraocular pressure that occurs when a person changes from a sitting position to lying on his back, utilizing applanation tonometry for both positions. The average pressure rise was 0.3 mm. Hg in...

متن کامل

Provocative testing for primary open-angle glaucoma in "senior citizens".

A group of "senior citizens" was studied with respect to applanation pressures, water-provocative tonography, and steroid-provocative testing. The results showed that considerable numbers of elderly individuals demonstrate applanation pressures greater than or equal to 20 mm. Hg and Po/C ratios after water greater than 100, and yet have normal disks and normal fields. It ivas concluded that suc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 20 6  شماره 

صفحات  -

تاریخ انتشار 1981