Effect of a new pelvic stabilizer (T-POD®) on reduction of pelvic volume and haemodynamic stability in unstable pelvic fractures.

نویسندگان

  • Edward C T H Tan
  • Sander F L van Stigt
  • Arie B van Vugt
چکیده

BACKGROUND Pelvic fractures, often the result of high energy blunt trauma, are associated with severe morbidity and mortality. A new pelvic stabilizer (T-POD®) provides secure and effective simultaneous circumferential compression of the pelvis. METHODS In this study we describe 15 patients with a prehospital untreated unstable pelvic fracture with signs of hypovolaemic shock with the T-POD®. Before and 2 min after applying the T-POD®, heart rate and blood pressure were measured. An X-ray before and directly after applying the T-POD® was made to measure the effect on reduction in symphyseal diastasis. RESULTS Application of the T-POD® reduced the symphyseal diastasis with 60% (p = 0.01). The mean arterial pressure (MAP) increased significant from 65.3 to 81.2 mm Hg (p = 0.03) and the heart rate declined from 107 beats per minute to 94 (p = 0.02). Out of ten patients in whom the circulatory response before and after the T-POD® was recorded, seven were good responders, one had a transient response and two responded poor. CONCLUSION In the acute setting, the T-POD® device has a clear compressive effect on the pelvic volume in unstable pelvic fractures. The T-POD® is therefore an effective and easy to use device in (temporarily) stabilizing the pelvic ring in haemodynamically unstable patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

Comparison of three different pelvic circumferential compression devices: a biomechanical cadaver study.

BACKGROUND Pelvic circumferential compression devices are designed to stabilize the pelvic ring and reduce the volume of the pelvis following trauma. It is uncertain whether pelvic circumferential compression devices can be safely applied for all types of pelvic fractures because the effects of the devices on the reduction of fracture fragments are unknown. The aim of this study was to compare ...

متن کامل

Effectiveness and complications of pelvic circumferential compression devices in patients with unstable pelvic fractures: a systematic review of literature.

BACKGROUND Pelvic fractures can cause massive haemorrhage. Early stabilisation and compression of unstable fractures is thought to limit blood loss. Reposition of fracture parts and reduction of pelvic volume may provide haemorrhage control. Several non-invasive techniques for early stabilisation have been proposed, like the specifically designed pelvic circumferential compression devices (PCCD...

متن کامل

Use of the trauma pelvic orthotic device (T-POD) for provisional stabilisation of anterior-posterior compression type pelvic fractures: a cadaveric study.

OBJECTIVE To demonstrate that a commercially available pelvic binder the trauma pelvic orthotic device (T-POD) is an effective way to provisionally stabilise anterior-posterior compression type pelvic injuries. METHODS Rotationally unstable pelvic injuries were created in 12 non-embalmed human cadaveric specimens. Each pelvis was then stabilised first with a standard bed sheet wrapped circumf...

متن کامل

Emergent pelvic fixation in patients with exsanguinating pelvic fractures.

BACKGROUND An alternative to embolization or external pelvic fixation (EPF) in patients with multiple pelvic fractures and hemorrhage is a pelvic orthotic device (POD), which may easily be placed in the resuscitation area. Little published information is available about its effectiveness. This study evaluated the efficacy of the POD compared with EPF in patients with life-threatening pelvic fra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Injury

دوره 41 12  شماره 

صفحات  -

تاریخ انتشار 2010