Real-time MRI comparisons of brass players: A methodological pilot study.

نویسندگان

  • Peter W Iltis
  • Erwin Schoonderwaldt
  • Shuo Zhang
  • Jens Frahm
  • Eckart Altenmüller
چکیده

This paper describes the use of real-time MRI at 30 frames/s in studying motor function within the oropharyngeal cavity of a trumpet, horn, trombone, and tuba player. Using Image J and customized MB-Ruler Pro software, analyses of discrete 33.3 ms snapshots of motion extracted from real-time MRI films obtained during an ascending five note sequence performed on a plastic practice device (B.E.R.P.) revealed inter-instrument differences in oropharyngeal cavity size and tongue conformation when moving from lower to higher notes. Tuba and trombone show a progressive decrease in oropharyngeal area featuring an upward and forward displacement of the tongue. Trumpet showed progressive increases in oropharyngeal area, with the posterior compartment showing the largest change, while horn essentially showed no change. A novel dynamic quantitative analysis method is also described utilizing Matlab. This method employs user-specified line profiles, aligned to the direction of the movement of interest. It takes advantage of time-varying pixel luminescence to derive spatial and temporal gradients. These gradients make possible the acquisition of kinematic data to describe movement in terms of slower position changes (spatial gradient) as well as fast, articulatory movements (temporal gradient). Spatial gradient analysis for the trumpet player demonstrates a progressive raising of the tongue during the ascending five note exercise. Temporal gradient analysis of double-tonguing revealed similarities in range of motion, anti-phase behavior, and frequency across instruments with respect to movements of the tongue tip and back of tongue. The paper concludes by making recommendations for extending these methods to studying musician's dystonia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-speed real-time magnetic resonance imaging of fast tongue movements in elite horn players.

This paper describes the use of high-speed real-time (RT) magnetic resonance imaging (MRI) in quantifying very rapid motor function within the oropharyngeal cavity of six elite horn players. Based on simultaneous sound recordings, the efficacy of RT-MRI films at 30 and 100 frames per second (fps) was assessed for tongue movements associated with double tonguing performance. Serial images with a...

متن کامل

Pilot Application of Biofeedback Training Program for Racket Sports Players

Background. A biofeedback program receives attention as an intervention program for athletes to regulate their psychological state. Objectives. The purpose was to apply for a heart rate variability (HRV) biofeedback training program and validate its effectiveness for racket sports players. Methods. The participants were eight elite sport athletes (three men and five women): five squash players...

متن کامل

Inefficiencies in Motor Strategies of Horn Players with Embouchure Dystonia: Comparisons to Elite Performers.

OBJECTIVE Motor control of the muscles of the face, lips, and tongue of horn players has traditionally been described from externally observed phenomena. Developments in real-time, high-speed magnetic resonance imaging (MRI) extend the scope of study to include descriptive and quantitative information from within the mouth. We employed these developments to compare oral movement strategies betw...

متن کامل

Improved Real-Time RT-PCR Assays of Two Colorectal Cancer Peripheral Blood mRNA Biomarkers: A Pilot Study

Background: Efficient screening for detection of colorectal cancer (CRC) at earlier stages reduces its mortality. The purpose of this study was to investigate expression of carcinoembryonic antigen (CEA) and human telomerase reverse transcriptase (hTERT) mRNA in peripheral blood of CRC patients and to present strategies for early detection screen test. Methods: Twenty seven patients in non-meta...

متن کامل

Suitability of Using Brass Ferrules as Packing in a Glass Distillation Column and Presenting a New Relationship between HETP and Pressure Drop

Brass Ferrules have been used as packing in a laboratory- scale glass distillation column approaching pilot plant size because of their availability in all sizes and low cost. The available size range is such that these ferrules could also be used in industry and the results of this study could be scaled up. The performance of the new packing has been compared with the performance of glass ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Human movement science

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2015