Symmetry of optic nerve head parameters measured by the heidelberg retina tomograph 3 in healthy eyes: the Blue Mountains Eye study.

نویسندگان

  • Haitao Li
  • Paul R Healey
  • Yasser M Tariq
  • Erdahl Teber
  • Paul Mitchell
چکیده

PURPOSE To assess the symmetry of optic nerve head parameters measured by the Heidelberg Retina Tomograph 3 (HRT 3) between fellow eyes in a normal elderly population. DESIGN Cross-sectional population-based study. METHODS Participants of the Blue Mountains Eye Study 10-year follow-up who did not have optic disc disease, including glaucoma, were included. Optic nerve head parameters measured by HRT 3 were compared between fellow eyes. The normal range of interocular asymmetry (larger disc minus smaller disc) was determined by the 2.5th and 97.5th percentiles. RESULTS A total of 1276 eligible participants had HRT scans of both eyes. HRT measurements in right eyes differed slightly in rim steepness and rim volume from those in left eyes (P < .05). The 2.5th and 97.5th percentile of interocular asymmetry limits were -0.41 and 0.45 for cup-to-disc ratio and -0.19 and 0.22 for cup-to-disc area ratio, respectively. The highest interocular correlation was found in disc area and cup area (r ranged from 0.74-0.76), whereas mean cup depth, cup volume, and retinal nerve fiber layer thickness had the poorest correlation (r ≤ 0.07). Greater optic disc area asymmetry was associated with a larger interocular difference in the other optic nerve head parameters. CONCLUSIONS There was minimal interocular difference and substantial interocular correlation in optic nerve head parameters measured by HRT 3. Interocular asymmetry greater than 0.2 for cup-to-disc area ratio was considered outside the normal range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Photorefractive Keratectomy on Optic Nerve Head Topography and Retinal Nerve Fiber Layer Thickness Measured by Heidelberg Retina Tomograph 3

PURPOSE To determine whether photorefractive keratectomy (PRK) has a significant effect on optic nerve head (ONH) parameters and peripapillary retinal nerve fiber layer (RNFL) thickness measured by the Heidelberg Retina Tomograph 3 (Heidelberg Engineering GmbH, Heidelberg, Germany) in eyes with low to moderate myopia. METHODS This prospective, interventional case series, includes 43 consecuti...

متن کامل

Relationship between short-wavelength automatic perimetry and Heidelberg retina tomograph parameters in eyes with ocular hypertension.

AIM To compare and correlate optic nerve head parameters obtained by Heidelberg retina tomograph (HRT) with short-wavelength automatic perimetry (SWAP) indices in eyes with ocular hypertension (OHT). METHODS One hundred and forty-six patients with OHT included in the present study. All subjects had reliable SWAP and HRT measurements performed within a 2wk period. The eyes were classified as n...

متن کامل

[Relationship between standard automated perimetry and optic nerve head topography performed with the Heidelberg Retina Tomograph].

PURPOSE To determine the correlations between optic nerve head (ONH) parameters measured with the Heidelberg Retina Tomograph (HRT), and the main outcomes of standard automated perimetry (SAP) in normal, ocular hypertensive, glaucoma suspects and glaucomatous subjects. METHODS Four hundred and twenty-three patients were enrolled in the study and classified into four groups depending on baseli...

متن کامل

Retinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer.

PURPOSE To compare retinal nerve fiber layer (RNFL) thickness measured by Heidelberg retina tomograph (HRT) and nerve fiber analyzer (GDx). METHODS Twenty eyes of 20 consecutive healthy subjects were recruited for this study. Each subject had a normal visual field and a normal optic nerve head, which was assessed by slit-lamp biomicroscopy using a 90 degrees lens. Using the HRT and GDx, RNFL ...

متن کامل

Diagnostic accuracy of the Moorfields Regression Analysis using the Heidelberg Retina Tomograph in glaucoma patients with visual field defects.

PURPOSE This study was designed to determine the specificity and sensitivity of the Heidelberg Retina Tomograph I (HRT) using the Moorfields Regression Analysis (MRA) in differentiating healthy from glaucomatous eyes. METHODS In this cross-sectional study, 74 eyes of 37 healthy subjects and 87 eyes of 47 glaucoma patients were examined with Octopus standard automated perimetry and HRT. Only o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of ophthalmology

دوره 155 3  شماره 

صفحات  -

تاریخ انتشار 2013