Preparation of Graphite Targets in the Gliwice Radiocarbon Laboratory for Ams
نویسندگان
چکیده
A line for preparation of graphite targets for accelerator mass spectrometry (AMS) radiocarbon dating has been built in the Gliwice 14C Laboratory. The AMS 14C measurements of our targets are performed in the Leibniz-Labor für Altersbestimmung, Kiel, Germany. The quality of our line has been tested in two series of AMS 14C measurements of background and Ox-II standard samples and by measurements of the amount of CO2 released during combustion of sample-free quartz tubes. Most background contamination in the first series was introduced during combustion, which has been greatly reduced by baking quartz tubes vacuum-sealed with CuO and Ag. The residual contamination (ca. 1.5 μg C) seems to come mostly from the quartz tubes themselves. At present, most of the contamination of the background is introduced during graphitization. The reproducibility of background preparations is satisfactory, especially for samples larger than 1.5 mg, when it is better than ± 0.09 pMC. Despite still significant contamination with low-14C carbon during the graphitization process (corresponding to 1.2 ± 0.2% of 14C-free carbon), the good reproducibility of the results allows us to use our line in routine 14C dating.
منابع مشابه
Measuring Submicron-Sized Fractionated Particulate Matter on Aluminum Impactor Disks.
Sub-micron sized airborne particulate matter (PM) is not collected well on regular quartz or glass fiber filter papers. We used a micro-orifice uniform deposit impactor (MOUDI) to fractionate PM into six size fractions and deposit it on specially designed high purity thin aluminum disks. The MOUDI separated PM into fractions 56-100 nm, 100-180 nm, 180-320 nm, 320-560 nm, 560-1000 nm, and 1000-1...
متن کاملBiological/Biomedical Accelerator Mass Spectrometry Targets. 1. Optimizing the CO2 Reduction Step Using Zinc Dust
Biological and biomedical applications of accelerator mass spectrometry (AMS) use isotope ratio mass spectrometry to quantify minute amounts of long-lived radioisotopes such as (14)C. AMS target preparation involves first the oxidation of carbon (in sample of interest) to CO 2 and second the reduction of CO 2 to filamentous, fluffy, fuzzy, or firm graphite-like substances that coat a -400-mesh ...
متن کاملBiological/Biomedical Accelerator Mass Spectrometry Targets. 2. Physical, Morphological, and Structural Characteristics
The number of biological/biomedical applications that require AMS to achieve their goals is increasing, and so is the need for a better understanding of the physical, morphological, and structural traits of high quality of AMS targets. The metrics of quality included color, hardness/texture, and appearance (photo and SEM), along with FT-IR, Raman, and powder X-ray diffraction spectra that corre...
متن کاملBiodegradation of Poly(butylene succinate) Powder in a Controlled Compost at 58 °C Evaluated by Naturally-Occurring Carbon 14 Amounts in Evolved CO2 Based on the ISO 14855-2 Method
The biodegradabilities of poly(butylene succinate) (PBS) powders in a controlled compost at 58 degrees C have been studied using a Microbial Oxidative Degradation Analyzer (MODA) based on the ISO 14855-2 method, entitled "Determination of the ultimate aerobic biodegradability of plastic materials under controlled composting conditions-Method by analysis of evolved carbon dioxide-Part 2: Gravime...
متن کاملIs Comparability of 14c Dates an Issue?: a Status Report on the Fourth International Radiocarbon Intercomparison
For more than 15 years, the radiocarbon community has participated in a series of laboratory intercomparisons in response to the issue of comparability of measurements as perceived within the wider user communities (Scott et al. 1990; Rozanski et al. 1992; Gulliksen and Scott 1995; Scott et al. 1997). In this report, we provide an update on the current 14C laboratory intercomparison and reflect...
متن کامل