Event Pileup in Charge-coupled Devices

نویسنده

  • JOHN E. DAVIS
چکیده

The problem of event pileup in single-photonÈcounting CCD cameras (e.g., in the X-ray regime) is discussed, and a solution to the problem is proposed. The resulting pileup equation includes the e†ects of grade migration and presents itself as a nonlinear modiÐcation to the standard integral equation used by forward-folding spectral-Ðtting programs. The e†ectiveness of the model is demonstrated by its application to the moderately piled zeroth-order data obtained by the Chandra X-Ray Observatory for the quasar S5 0836]7104. Subject headings : instrumentation : detectors È methods : analytical È methods : data analysis È X-rays : general

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pile - up correction for the Swift - XRT observations in WT mode

— The detector at the focal plane of the Swift X-ray Telescope (XRT) supports four readout modes, automatically changed on board, to cover the dy-namical range of fluxes and rapid variability expected from GRB afterglows. The Windowed Timing (WT) mode is used for sources with flux higher than a few mCrab and is obtained by compressing 10 rows into a single row, and then reading out only the cen...

متن کامل

ACIS Pileup: Analysis of XRCF Phase H Data

Results of analysis of XRCF ACIS pileup tests H-IAI-CR-1.001, 1.003 and 1.005 are presented. In this series of tests with monotically increasing Al Kα source flux (ranging from ∼ 0.3 to ∼ 3.0 ACIS counts/frame in the absence of pileup) incident on a frontside-illuminated CCD, various symptoms of pileup — image degradation, grade migration, count rate non-linearity, and event pulse height confus...

متن کامل

ar X iv : a st ro - p h / 01 11 00 3 v 1 3 1 O ct 2 00 1 Simulating CCDs for the Chandra Advanced CCD Imaging Spectrometer

We have implemented a Monte Carlo algorithm to model and predict the response of various kinds of CCDs to X-ray photons and minimally-ionizing particles and have applied this model to the CCDs in the Chandra X-ray Observatory's Advanced CCD Imaging Spectrometer. This algorithm draws on empirical results and predicts the response of all basic types of X-ray CCD devices. It relies on new solution...

متن کامل

مقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندان‌های اندو شده (مطالعه آزمایشگاهی)

  Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth.   Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and roo...

متن کامل

SoftKiller, a particle-level pileup removal method

Existing widely used pileup removal approaches correct the momenta of individual jets. In this article we introduce an event-level, particle-based pileup correction procedure, SoftKiller. It removes the softest particles in an event, up to a transverse momentum threshold that is determined dynamically on an event-by-event basis. In simulations, this simple procedure appears to be reasonably rob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001