Isomeric differentiation of polycyclic aromatic hydrocarbons using silver nitrate reactive desorption electrospray ionization mass spectrometry.
نویسندگان
چکیده
RATIONALE Polycyclic aromatic hydrocarbons (PAHs) are nonpolar and difficult to detect by desorption electrospray ionization. We present a new detection method based on cationization with silver ions, which has the added advantage of being able to differentiate PAHs with the same mass but different structure. METHODS 9,10-Diphenylanthracene and triptycene, in addition to four different groups of PAH isomers: (1) anthracene and phenanthrene, (2) pyrene and fluoranthene, (3) benz[a]anthracene, benz[b]anthracene (tetracene), and chrysene (4) benzo[a]pyrene and benzo[k]fluoranthene, were deposited on a paper surface and bombarded with methanol droplets containing silver nitrate. The resulting microdroplets entered a quadruple mass spectrometer for mass analysis. RESULTS The mass spectrum shows [PAH](+), [Ag + OH + PAH](+), and [Ag(PAH)(n)](+) (n = 1, 2) (and [PAH + O(2)](+) in the case of benz[b]anthracene) ions. PAHs having a bay structure, such as phenanthrene, showed a different tendency to interact with silver ions from those PAHs having a linear arrangement of the fused benzene rings, such as anthracene. The ratios of the [PAH](+) peak intensity to that of [Ag-PAH](+), [Ag + OH + PAH](+), [Ag(PAH)(2)](+), and [PAH + O(2)](+) were used to differentiate the PAH isomers sharing the same molecular formula with different structures. For isomeric mixtures the [PAH](+) to [Ag + OH + PAH](+) ratio was found to be the most useful parameter. The uncertainty in the mole fraction of an isomeric mixture was ±0.09, ±0.13, ±0.25, and ±0.1 for phenanthrene-anthracene, fluoranthene-pyrene, benz[a]anthracene-chrysene, and benzo[a]pyrene-benzo[k]fluoranthene, respectively. CONCLUSIONS A simple method has been developed for the detection of PAHs in desorption electrospray ionization mass spectrometry based on Ag(I) cationization. The method showed a capability to differentiate PAHs isomers (having the same molecular mass) in isomeric mixture with an uncertainty in the mole fraction of about ±0.1. At high inlet temperature and voltage, this method showed better sensitivity but less ability to differentiate between isomeric species.
منابع مشابه
Silver complexation and tandem mass spectrometry for differentiation of isomeric flavonoid diglycosides.
For detection and differentiation of isomeric flavonoids, electrospray ionization mass spectrometry is used to generate silver complexes of the type (Ag + flavonoid)+. Collisionally activated dissociation (CAD) of the resulting 1:1 silver/flavonoid complexes allows isomer differentiation of flavonoids. Eighteen flavonoid diglycosides constituting seven isomeric series are distinguishable from e...
متن کاملLiquid chromatography-mass spectrometry and strategies for trace-level analysis of polar organic pollutants.
Liquid chromatography-mass spectrometry using atmospheric pressure ionization (LC-API-MS) has drastically changed the analytical methods used to detect polar pollutants in water. The present status of application of this technique to organic water constituents is reviewed. The selection of the appropriate LC conditions, whether reversed-phase liquid chromatography, ion-pair chromatography, capi...
متن کاملDirect measurement of the glucuronide conjugate of 1-hydroxypyrene in human urine by using liquid chromatography with tandem mass spectrometry.
To evaluate human exposure to polycyclic aromatic hydrocarbons (PAHs), we developed a rapid, simple and sensitive method for determining 1-hydroxypyrene-glucuronide (1-OHP-G) in human urine. To improve precision, a deuterated glucuronide was used as an internal standard. The method requires only 1 mL of urine. The urine was treated with a mixed-mode anion-exchange and reversed-phase solid-phase...
متن کاملBiotransformation of the high-molecular weight polycyclic aromatic hydrocarbon (PAH) benzo[k]fluoranthene by Sphingobium sp. strain KK22 and identification of new products of non-alternant PAH biodegradation by liquid chromatography electrospray ionization tandem mass spectrometry
A pathway for the biotransformation of the environmental pollutant and high-molecular weight polycyclic aromatic hydrocarbon (PAH) benzo[k]fluoranthene by a soil bacterium was constructed through analyses of results from liquid chromatography negative electrospray ionization tandem mass spectrometry (LC/ESI(-)-MS/MS). Exposure of Sphingobium sp. strain KK22 to benzo[k]fluoranthene resulted in t...
متن کاملIsomer discrimination of polycyclic aromatic hydrocarbons in the Murchison meteorite using two-color resonant two-photon ioniz
We have used two-color resonant two-photon ionization (2C-R2PI) mass spectrometry to discriminate between isomers of polycyclic aromatic hydrocarbons in the Murchison meteorite. We measured the 2C-R2PI spectra of chrysene and triphenylene seeded in a supersonic jet by laser desorption. Since each isomer differs in its R2PI spectrum, we can distinguish between isomers using wavelength dependent ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 26 17 شماره
صفحات -
تاریخ انتشار 2012