Measuring stiffness can define healing of tibial fractures.
نویسندگان
چکیده
We measured fracture stiffness in 212 patients with tibial fractures treated by external fixation. In the first 117 patients (group 1) the decision to remove the fixator and allow independent weight-bearing was made on clinical grounds. In the other 95 patients (group 2) the frames were removed when the fracture stiffness had reached 15 Nm/degree. In group 1 there were eight refractures and in group 2 there was none (p = 0.02, Fisher's exact test). The time to independent weight-bearing was longer in group 1 (median 24 weeks) than in group 2 (21.7 weeks, p = 0.02). The greater precision of our objective measurement was associated with a reduction in refracture rate and in the time taken to achieve independent weight-bearing. We consider that a stiffness of 15 Nm/degree in the sagittal plane provides a useful definition of union of tibial fractures.
منابع مشابه
Clinical implications of stiffness and strength changes in fracture healing.
In the assessment of fracture healing by monitoring stiffness with vibrational analysis or instrumented external fixators, it has been assumed that there is a workable correlation between stiffness and strength. We used four-point bending tests to study time-related changes in stiffness and strength in healing tibial fractures in sheep. We aimed to test the validity of the measurement of stiffn...
متن کاملFracture stiffness as a guide to the management of tibial fractures.
We have studied the progression of healing in 103 unstable fractures of the tibia. In 76 patients we removed the external fixator once the stiffness had reached 15 Nm/degrees in the sagittal plane. Deformity at the site of the fracture subsequently occurred in four patients. In a further 27, we measured stiffness in several planes and removed the fixator only when the stiffness reached 15 Nm/de...
متن کاملComparison of a new braid fixation system to an interlocking intramedullary nail for tibial osteotomy repair in an ovine model.
OBJECTIVES To compare bone healing of tibial osteotomy repaired with Nitinol wire braid and hardened steel rods (Braid system) and polymethylmethacrylate bone cement with an interlocking intramedullary (IM) nail fixation in an ovine model. STUDY DESIGN In vitro and in vivo experimental study. ANIMALS Adult female sheep (n=22). METHODS Using sheep tibia, a middiaphyseal transverse osteotom...
متن کاملCombined Use of Percutaneous Canulated Screws and External or Internal Fixationfor Less Invasive Treatment of Tibial Plateaux Fractures
The classic way of treatment of tibial plateau fractures with an extensive approach, opening of the knee and compressive internal fixation can lead to major complications such as infection, skin necrosis and knee stiffness. Here we present a less invasive and thus safer surgical technique, and its indications and results. Twenty patients with various types of fractures according to Schatzker’s ...
متن کاملStiffness measurements to assess healing during leg lengthening. A preliminary report.
We describe a technique for measuring the stiffness of regenerate bone after leg lengthening. This allows early identification of slow healing by reference to normal patterns. We determined the time of removal of the fixator from clinical and radiological information independent of the stiffness result. In a series of 30 leg lengthenings there were no refractures when the tibial stiffness had r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 76 3 شماره
صفحات -
تاریخ انتشار 1994