Detection of Reactive Oxygen Species by a Carbon-Dot-Ascorbic Acid Hydrogel.
نویسندگان
چکیده
Detection of reactive oxygen species (ROS) is important in varied biological processes, disease diagnostics, and chemotherapeutic drug screening. We constructed a ROS sensor comprising an ascorbic-acid-based hydrogel encapsulating luminescent amphiphilic carbon-dots (C-dots). The sensing mechanism is based upon ROS-induced oxidation of the ascorbic acid units within the hydrogel scaffold; as a consequence, the hydrogel framework collapses resulting in aggregation of the C-dots and quenching of their luminescence. The C-dot-hydrogel platform exhibits high sensitivity and detected ROS generated chemically in solution and in actual cell environments. We demonstrate application of the C-dot-hydrogel for evaluating the efficacy of a chemotherapeutic substance, underscoring the potential of the system for drug screening applications.
منابع مشابه
Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode
In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...
متن کاملSimultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode
In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...
متن کاملDetection of Ascorbic Acid in Biological Samples by a New Modified Glassy Carbon Electrode
The present work describes the construction of a new modified electrode by casting the appropriate mixture of a metallocene, which has been introduced in the experimental part, as a mediator at the surface of glassy carbon (GC) electrode. The proposed modified GC electrode was used for the determination of ascorbic acid (AA) in phosphate buffer (PB) solution (pH = 4.0). When compared to bare GC...
متن کاملCarbon-dot–hydrogel for enzyme-mediated bacterial detection
A hybrid carbon-dot (C-dot)–hydrogel matrix was constructed and employed for detection of bacteria. The transduction mechanism is novel, based upon cleavage of ester bonds within the hydrogel scaffold by bacterially-secreted esterases; the ensuing fluidization of the hydrogel resulted in aggregation of the embedded C-dots and consequent quenching of their fluorescence. We show that the C-dot–hy...
متن کاملIron Overload Induced Apoptotic Cell Death in Isolated Rat Hepatocytes Mediated by Reactive Oxygen Species
Isolated rat hepatocytes in culture were incubated with different concentrations of iron-sorbitol (50, 100, 150, and 200 µM) to assess the changes in reactive oxygen species (ROS) and lipid peroxidation leading to apoptotic hepatocyte cell death. The viability of hepatocytes was declined depending on the iron concentration. One hour incubation of the cells with 100 µM iron resulted in decreased...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 89 1 شماره
صفحات -
تاریخ انتشار 2017