Efficacy of a new full face mask for noninvasive positive pressure ventilation.
نویسندگان
چکیده
Previous studies have shown that noninvasive positive pressure ventilation (NPPV) improves gas exchange in acute and chronic respiratory failure. However, some patients are unable to tolerate NPPV due to air leaks around the mask, facial discomfort, and claustrophobia. A new mask that covers the entire face (Total, Respironics, Monroeville, Pa), attempts to overcome these obstacles. We studied the efficacy of NPPV via the Total face mask (TFM) in nine patients with chronic respiratory failure. In three patients, respiratory failure was due to chronic obstructive lung disease, and in six patients, it was secondary to restrictive disorders. None of the patients were previously able to tolerate NPPV via nasal (N) or nasal-oral (NO) masks. At baseline, all patients had impaired gas exchange with low PaO2/FIO2 (241 +/- 14), elevated PaCO2 (79 +/- 5 mm Hg), and poor functional status (1.89 +/- 1.45, on a scale of 1 to 7). After NPPV in the hospital for 7.1 +/- 1.5 h per night for 22 +/- 26 days, the PaCO2 fell to 59 +/- 3 mm Hg, and the PaO2/FIO2 rose to 304 +/- 27. Following nocturnal NPPV via the TFM for 6.7 +/- 1.5 h a night 6 +/- 5 weeks after hospital discharge, sustained improvements in PaCO2 (58 +/- 3 mm Hg, p < 0.05), PaO2/FIO2 (304 +/- 18), and functional status (5.38 +/- 1.06, p < 0.05) were observed. In four patients, measurements of respiratory rate, tidal volume, minute ventilation, dyspnea, discomfort with the face mask, and mask and mouth leaks were made during 30-min sessions of NPPV applied at constant levels via all three masks (N, NO, TFM). Discomfort with the face mask (0.38 +/- 0.18 vs 1.44 +/- 0.34 vs 2.38 +/- 0.32, p < 0.05) and mask leaks (0.44 +/- 0.18 vs 1.89 +/- 0.39 vs 1.89 +/- 0.35, p < 0.05) were least during NPPV via TFM compared with the N or NO masks, respectively. Moreover, expired tidal volume was highest (804 +/- 10 vs 498 +/- 9 vs 537 +/- 13 ml, p < 0.05) and PaCO2 lowest (51 +/- 2 vs 57 +/- 2 vs 58 +/- 3, p < 0.05) during NPPV via the TFM compared with N or NO masks. We conclude that NPPV delivered via a Total mask ensures a comfortable, stable patient-mask interface and improves gas exchange in selected patients intolerant of more conventional N or NO masks.
منابع مشابه
Acute physiologic effects of nasal and full-face masks during noninvasive positive-pressure ventilation in patients with acute exacerbations of chronic obstructive pulmonary disease.
OBJECTIVE To assess the efficacy of and patient tolerance for nasal and full-face masks during noninvasive positive-pressure ventilation (NPPV) with patients suffering acute exacerbations of chronic obstructive pulmonary disease. SETTING A respiratory medicine ward of a referral hospital. METHODS Fourteen patients were randomized to 2 groups. Seven used nasal masks and 7 used full-face mask...
متن کاملFull face mask for noninvasive positive-pressure ventilation in patients with acute respiratory failure.
BACKGROUND Noninvasive positive-pressure ventilation (NPPV) is commonly used to improve ventilation and oxygenation in patients with acute respiratory failure (ARF). Mask leak and intolerance due to facial discomfort or claustrophobia often occur with NPPV and are frequently cited reasons for treatment failure. METHODS Retrospective review of patient records from a tertiary-care referral hosp...
متن کاملN Equipment and Techniques for Noninvasive Ventilation
livery of mechanical ventilation to patients with respiratory failure without the requirement of an artificial airway. The key change that led to the recent increase in the use of this technique occurred in the early 1980s with the introduction of the nasal continuous positive airway pressure mask for the treatment of obstructive sleep apnea. Studies published in the 1990s that evaluated the ef...
متن کاملNasal versus full face mask for noninvasive ventilation in chronic respiratory failure.
This study was undertaken to determine the efficacy of nasal mask (NM) versus full face mask (FFM) for the delivery of noninvasive ventilation (NIV) in subjects with nocturnal hypoventilation. A total of 16 patients (11 males) were enrolled, all with nocturnal hypoventilation currently treated at home with NIV via pressure preset devices. Subjects underwent full polysomnography on three occasio...
متن کاملThe total face mask is more comfortable than the oronasal mask in noninvasive ventilation but is not associated with improved outcome.
BACKGROUND Noninvasive positive-pressure ventilation (NPPV) is commonly used to improve ventilation and oxygenation and avoid endotracheal intubation and mechanical ventilation. Although clinically indicated, most patients fail to use NPPV due to mask intolerance. A total face mask was designed to increase compliance, but whether this translates into better outcome (improvement in clinical and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 106 4 شماره
صفحات -
تاریخ انتشار 1994