Discrimination of Short-duration (two Pulse) Flashes as a Function of Signal Luminance and Method of Measurement
نویسنده
چکیده
The recent introduction of strobe lights for anticollision purposes raises the possibility of using temporal patterns of short duration flashes as information carrying signals. The current experiments are concerned with the detection of the minimum duration dark interval between signal light pulses as a function of signal luminance and the psychophysical method of measurement. Experiment I tested the theory of signal detectability (TSD) prediction that obse~ver sensitivity is independent of the psychophysic?l method used in measurement. Discrimination of a constant duration comparison stimulus (three msec) and a variable duration test stimulus (seven to 32 msec) was measured with a two-alternative Forced-Choice (FC) procedure and a Yes-No procedure. Sensitivity was comparable under the two psychophysical procedures, thus supporting the application of TSD to the sensory, processes involved in discrimination of two-pulse stimuli. Experiment II measured discrimination with the FC procedure at three luminance levels: 31.8, 318, and 3183 candelas per square meter. Discriminability increased with luminance. Thus, pulses separated by a dark interval short enough so that only a single flash is seen over the entire scotopic intensity range may, however, be seen at photopic intensities as two pulses, or appear to flicker, or otherwise appear to be of different character. To maintain a homogeneous flash appearance over the entire range of signal intensities, the dark interval duration for multi-pulse flashes should be determined for the highest intensity condition at which operational observation is anticipated. I. Introduction. The recent introduction of strobe lights for anticollision raises the possibility of using temporal patterns of short duration flashes as information carrying signals. An i:::1dividual flash can be produced by multiple brief light pulses, simulaneous or successive, as long as the component pulses are sufficiently close in time and space as to not be perceptually resolvable. The duration and intensity of a particular flash thus produced can be varied by ma:::1ipulation of the temporal spacing and the number of component pulses. Variation of signal intensity will also normally occur with varying visual range, windshield transmissivity, atmospheric conditions and any other factors which affect the amount of light reaching the observer's eye. 1 In order to design multi-pulse signal flashes it is essential to know how the minimum detectable dark interval between brief pulses varies with signal intensity. The effect of luminance on the discrimination of duration differences between multi-pulse flashes is examined for the limiting case of two-pulsfl stimuli presented under night flight conditions.
منابع مشابه
Signal detection Using Rational Function Curve Fitting
In this manuscript, we proposed a new scheme in communication signal detection which is respect to the curve shape of received signal and based on the extraction of curve fitting (CF) features. This feature extraction technique is proposed for signal data classification in receiver. The proposed scheme is based on curve fitting and approximation of rational fraction coefficients. For each symbo...
متن کاملA Quantitative Study of the Effect of Electroporation on the Electropermeability and Cell Survival
Introduction: Electroporation is a practical technique used to transport the molecules across the cell membrane. The utilization of fluorescent molecules is the method widely used to evaluate the electropermeability of cell membrane as a result of pulse application. It is also possible to use mathematical methods to predict the changes caused in cell electropermeability as a result of the chang...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...
متن کاملIncreasing the Accuracy of Blood Hematocrit Measurement by Triplicate Wavelength Photoplethysmography Method
Background and objectives: The importance of continuous monitoring and rapid and accurate informing of changes in blood components (e.g., percentage of hematocrit [HCT]), especially in acute conditions, has motivated researchers to use non-invasive measurement methods. Therefore, this study aimed to evaluate the association between blood HCT and photoplethysmographic signal and the possibility ...
متن کاملA reduction in stimulus duration can improve wavelength discriminations mediated by short-wave cones.
Virtually all visual discriminations become less accurate when either the luminance or the duration of the stimulus is reduced. An exception is found for wavelength discriminations near 460 nm, where an increase in either luminance or duration can cause the threshold to rise. For flashes of 100 msec or less, the critical variable is the total energy of the flash (i.e. the product of retinal ill...
متن کامل