Pii: S1010-7940(99)00211-0
نویسندگان
چکیده
Objective: Dynamic aortomyoplasty using Latissimus Dorsi muscle (LDM) has been shown to improve myocardial function. However, systematic examination of the effects of stimulation parameters on aortic wrap function has not been done. Thus, the present study measures the direct effect of stimulation voltage, pulse train duration, frequency of the pulses, and the duration of the stimulation delay from R wave on the aortic wrap function. Methods: In eight female goats, the left LDM was wrapped around the descending aorta. The muscle was then subjected to electrical stimulation, altering frequency of stimulation pulses (16.6, 20, 25, 33 and 50 Hz), amplitude (2, 4, 6, 8 and 10 V), and number of pulses (2, 4, 6, 8 and 10 pulses) in a train stimulation. Left ventricular, aortic pressure, and pressure generated by LDM on aorta (wrap pressure) was measured. The changes in hemodynamic parameters mentioned above were calculated and compared for different stimulation parameters during unassisted and assisted cardiac cycles. Results: Aortomyoplasty counterpulsation using LDM provided signi®cant improvement in wrap pressure (78 mmHg ^ 2), aortic diastolic pressure, and changes in aortic diastolic pressure from 2 to 4 V (P , 0:05). Further increase in amplitude did not make any signi®cant improvements of the above mentioned parameters. Signi®cant augmentation of wrap pressure (82 mmHg ^ 2), aortic diastolic pressure (79 mmHg ^ 3) and changes in aortic diastolic pressure (12 mmHg ^ 1) occurred at 6 pulses (P , 0:05). Other changes in number of pulses did not show any signi®cant improvements. Signi®cant improvement of wrap pressure (80 mmHg ^ 2), aortic diastolic pressure (73 mmHg ^ 3) and changes in aortic diastolic pressure (12 mmHg ^ 1) was observed with a frequency of 33 Hz. To examine a wide range of delays from the onset of the QRS complex to LDM stimulation, stimulation was delivered randomly. The exact delay was determined from the ECG signal and superimposed LDM stimulation pulses. Conclusions: In this study we present a new measurement, wrap pressure. We also present that in aortomyoplasty using LDM, the most signi®cant improvement in wrap pressure, aortic diastolic pressure and changes in aortic diastolic pressure occurs when the stimulation consists of an amplitude of 4 V, a frequency of 33 Hz and a train stimulation of 6 pulses. q 1999 Elsevier Science B.V. All rights reserved.
منابع مشابه
Pii: S1010-7940(99)00225-0
Haemangiopericytoma is a rare, highly vascular, slow-growing tumour which has both malignant and benign varieties. We report a case of a 63-year-old man in whom it was treated by initial radiotherapy followed by complete surgical excision. The preoperative radiotherapy markedly reduced the vascularity of the tumour. A brief review of the pathology and nature of tumour is provided. q 1999 Elsevi...
متن کاملPii: S1010-7940(99)00263-8
The integration of minimally invasive coronary artery bypass grafting with catheter-based interventions is being practiced with increasing frequency both in the standard and high risk patient populations. The procedures can be staged on different days or done concurrently in either an operative cathlab or an operating room with imaging capabilities. The new clinical issues raised with these new...
متن کاملPii: S1010-7940(01)01137-x
We report the laparoscopic transhiatal thoracic duct ligation to solve postoperative chylothorax after right total pleurectomy for malignant diffuse mesothelioma. q 2002 Elsevier Science B.V. All rights reserved.
متن کاملPii: S1010-7940(99)00150-5
A patient presenting with a pacemaker lead infection and tricuspid regurgitation underwent a minimally invasive video-assisted tricuspid valve replacement. The valve was approached through a right anterior mini thoracotomy. Under thoracoscopic vision and peripheral cardiopulmonary bypass, a catheter was placed on the ascending aorta for antegrade cardioplegia delivery. A transthoracic aortic cr...
متن کاملPii: S1010-7940(99)00248-1
We describe a simple technique for the delivery of high haematocrit blood cardioplegia. The system allows for a user de®ned, variable concentration of warm, tepid or cold solution to be delivered. The concentration can be varied based upon the pressure regulated ̄ow of blood, and is manipulated by a four variable equation calculated by a spreadsheet formula stored in a hand-held computer. The s...
متن کاملPii: S1010-7940(01)00715-1
Constrictive pericarditis is a relatively rare clinical manifestation nowadays. We present the case of an HIV-positive patient with constrictive calci®ed pericarditis due to an infection with Mycobacterium tuberculosis. Pericardectomie was performed. The therapeutical approach is discussed and the literature is reviewed. q 2001 Elsevier Science B.V. All rights reserved.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999