Effect of retroreflection on a Fizeau phase-shifting interferometer.
نویسندگان
چکیده
Phase errors in a Fizeau phase-shifting interferometer caused by multiple-reflected beams from a retroreflective optics, such as a corner cube and a right-angle prism, are studied. Single- and double-pass configurations are presented, and their measurement results are compared. An attenuator is not needed in a double-pass configuration because light is reflected by the retroreflective optics twice and the reference surface once and hence the intensities match. It is more accurate to test a corner cube or a right-angle prism in a double-pass configuration than in a single-pass configuration. Simulations and experimental results are presented.
منابع مشابه
Effects of birefringence on Fizeau interferometry that uses a polarization phase-shifting technique.
Interferometers that use different states of polarization for the reference and the test beams can modulate the relative phase shift by using polarization optics in the imaging system. Thus the interferometer can capture simultaneous images that have a fixed phase shift, which can be used for phase-shifting interferometry. As all measurements are made simultaneously, the interferometer is not s...
متن کاملInstantaneous phase-shift Fizeau interferometer utilizing a synchronous frequency shift mechanism
An on-axis, vibration insensitive, polarization Fizeau interferometer is realized through the use of a pixelated polarization mask spatial carrier phase shifting technique in conjunction with a high coherence source and a polarization frequency shift device. In this arrangement, differential motion between the test and reference surfaces, in conjunction with the polarization frequency shift dev...
متن کامل-
In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...
متن کاملPhase-shifting errors in interferometric tests with high-numerical-aperture reference surfaces.
The errors introduced by moving a spherical reference surface to generate a phase shift between the beams in a Fizeau interferometer are discussed.
متن کاملFizeau interferometer for measurement of plasma electron current
A high-resolution, vertically viewing far-infrared polarimeter-interferometer system is currently used on the Madison symmetric torus (MST) reversed-field pinch (RFP) to measure the plasma electron density and toroidal current density via Faraday rotation. In this article, we propose a scheme to measure the well-known Fizeau effect, whereby through modest modification of the existing apparatus,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 32 19 شماره
صفحات -
تاریخ انتشار 1993